| Electronic Components Datasheet Search |
|
VCBUP7CT7 Datasheet(PDF) 157 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
VCBUP7CT7 Datasheet(HTML) 157 Page - Texas Instruments |
|
157 / 355 page ![]() TMS320DM6467 www.ti.com SPRS403H – DECEMBER 2007 – REVISED JUNE 2012 Table 7-8. PLL1 and PLL2 Multiplier Ranges -594 -729 PLL MULTIPLIER (PLLM) MIN MAX MIN MAX PLL1 Multiplier x14 x22 x14 x27 PLL2 Multiplier x14 x22 x14 x23 Table 7-9. PLLC1 Clock Frequency Ranges -594 -729 CLOCK SIGNAL NAME UNIT MIN MAX MIN MAX DEV_MXI/DEV_CLKIN(1) 20 30 20 30 MHz PLLOUT 400 594 400 729 MHz SYSCLK1 (PLLDIV1 Domain) 594 729 MHz (1) DEV_MXI/DEV_CLKIN input clock is used for both PLL Controllers (PLLC1 and PLLC2). Table 7-10. PLLC2 Clock Frequency Ranges -594 -729 CLOCK SIGNAL NAME UNIT MIN MAX MIN MAX DEV_MXI/DEV_CLKIN(1) 20 30 20 30 MHz PLLOUT 400 594 400 621 MHz PLL2_SYSCLK1 (to DDR2 PHY) 594 621 MHz (1) DEV_MXI/DEV_CLKIN input clock is used for both PLL Controllers (PLLC1 and PLLC2). Both PLL1 and PLL2 have stabilization, lock, and reset timing requirements that must be followed. The PLL stabilization time is the amount of time that must be allotted for the internal PLL regulators to become stable after the PLL is powered up (after the PLLCTL.PLLPWRDN bit goes through a 1-to-0 transition). The PLL should not be operated until this stabilization time has expired. This stabilization step must be applied after these resets—a Power-on Reset, a Warm Reset, or a Max Reset, as the PLLCTL.PLLPWRDN bit resets to a "1". For the PLL stabliziation time value, see Table 7-11. The PLL reset time is the amount of wait time needed for the PLL to properly reset (writing PLLRST = 1) before bringing the PLL out of reset (writing PLLRST = 0). For the PLL reset time value, see Table 7-11. The PLL lock time is the amount of time needed from when the PLL is taken out of reset (PLLRST = 0 with PLLEN = 0) to when to when the PLL controller can be switched to PLL mode (PLLEN = 1). For the PLL lock time value, see Table 7-11. Table 7-11. PLL1 and PLL2 Stabilization, Lock, and Reset Times PLL STABILIZATION/ MIN NOM MAX UNIT LOCK/RESET TIME PLL Stabilization Time 150 μs PLL Lock Time 2000C(1) ns PLL Reset Time 128C(1) ns (1) C = CLKIN cycle time in ns. For example, when DEV_MXI/DEV_CLKIN or AUX_MXI/AUX_CLKIN frequency is 27 MHz, use C = 37.037 ns. For details on the PLL initialization software sequence, see the TMS320DM646x DMSoC ARM Subsystem Reference Guide (literature number SPRUEP9). For more information on the clock domains and their clock ratio restrictions, see Section 7.3.4, DM6467 Power and Clock Domains. Copyright © 2007–2012, Texas Instruments Incorporated Peripheral Information and Electrical Specifications 157 Submit Documentation Feedback Product Folder Link(s): TMS320DM6467 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |