  L2421 Datasheet HTML 1Page - Hamamatsu Corporation L2421 Datasheet HTML 2Page - Hamamatsu Corporation L2421 Datasheet HTML 3Page - Hamamatsu Corporation L2421 Datasheet HTML 4Page - Hamamatsu Corporation L2421 Datasheet HTML 5Page - Hamamatsu Corporation L2421 Datasheet HTML 6Page - Hamamatsu Corporation L2421 Datasheet HTML 7Page - Hamamatsu Corporation L2421 Datasheet HTML 8Page - Hamamatsu Corporation L2421 Datasheet HTML 9Page - Hamamatsu Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 14 page
background image
2
GLASS BULB
ANODE
HIGH PURITY Xe GAS
HIGH PURITY Hg
CATHODE
MOVEMENT OF ARC POINT
Conventional Mercury-Xenon Lamps have a shortcoming
in that their arc point can move gradually as a result of cath-
ode erosion during normal operation. The SQ Mercury-Xe-
non Lamp uses a specially developed, durable cathode
which shows negligible erosion with operating time. There-
fore, once the optical system is set up, it is no more neces-
sary to adjust it over the operating life of the lamp.
Figure 3: Comparison of Cathode Erosion
Super-Quiet Mercury-Xenon Lamps
After 5 h Operation
After 1000 h Operation
Conventional Lamp
After 5 h Operation
After 1000 h Operation
POWER SUPPLY
Mercury-Xenon Lamps must have a stable light emission
output to be used as light source for measuring purposes.
Therefore, because the output radiant intensity is approxi-
mately in proportion to the current flowing into the lamp, a
stabilized power supply should be provided for the lamp.
Figure 4 shows a diagram of such a stabilized power supply
consisting of a main power supply and a trigger power sup-
ply. Stabilized power supplies specifically designed for
Hamamatsu SQ Mercury-Xenon Lamps are also available
from Hamamatsu (See page 8).
Figure 4:
Block Diagram of Stabilized Power Supply
MAIN POWER
SUPPLY
TRIGGER POWER SUPPLY
ANODE
CATHODE
AC
TLSXC0034EA
CONSTRUCTION AND OPERATION
Figure 1 shows the construction of the lamp. The lamp has
same shape as that of the conventional Xenon short-arc
lamp or super-high-pressure mercury lamp with two elec-
trodes of cathode and anode. The electrodes face each other
in an oval glass bulb which is filled with a certain amount of
mercury and high purity xenon gas under several MPa of
pressure.
Figure 1:
Construction of Lamp
TLSXC0033EA
As for operation, Mercury-Xenon Lamps utilize the principle
of light emission by arc discharge. This type of lamp must
be installed either vertically with the anode above the cath-
ode or horizontally. Initially an arc discharge triggers the
lamp to start its emission. The lamp maintains stable op-
eration via an applied dc voltage. The light emission from
the arc discharge has strong line spectra ranging from ul-
traviolet to infrared radiation. After the lamp is switched on,
emission of light from the xenon gas occurs. This is accom-
panied by efficient vaporization of the mercury, and emis-
sion of light for the mercury spectrum. It takes several min-
utes for the radiant intensity to reach the maximum value,
as the gas pressure inside the bulb increases after the bulb
is lit up until it reaches a thermal equilibrium. The gas pres-
sure during operation is approximately 3 times higher than
that when the lamp is not operated. Figure 2 shows the typi-
cal temperature distribution of a lamp bulb after thermal
equilibrium.
Figure 2:
Typical Temperature Distribution of a Lamp Bulb
(at Vertical Operation)
ARC POINT
100
50
200
300
500
400
BULB TEMPERATURE (
°C)
TLSXB0007EA
STABILITY OF ARC (FLUCTUATION)
The elimination of arc fluctuation has been an important is-
sue for Mercury-Xenon Lamp users in precision light mea-
suring applications. Hamamatsu has studied this “fluctua-
tion” carefully, and ascertained that it is mostly an irregular
movement of the arc point caused by a lack of electrons
emitted from the cathode. The Hamamatsu SQ Mercury-
Xenon Lamp has solved this problem by incorporating a high-
performance cathode especially developed for this purpose.
SUPER-QUIET MERCURY-XENON LAMPS



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com