Back Button DA9063L Datasheet HTML 83Page - Dialog Semiconductor DA9063L Datasheet HTML 84Page - Dialog Semiconductor DA9063L Datasheet HTML 85Page - Dialog Semiconductor DA9063L Datasheet HTML 86Page - Dialog Semiconductor DA9063L Datasheet HTML 87Page - Dialog Semiconductor DA9063L Datasheet HTML 88Page - Dialog Semiconductor DA9063L Datasheet HTML 89Page - Dialog Semiconductor DA9063L Datasheet HTML 90Page - Dialog Semiconductor DA9063L Datasheet HTML 91Page - Dialog Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 87 / 173 page
background image
DA9063L
System PMIC for Mobile and Automotive Applications
Datasheet
DA9063L_2v1
05-Apr-2017
CFR0011-120-00
87 of 173
© 2017 Dialog Semiconductor
6.11.4.3
A8, A9, A10: Automatic Regulator Monitor with Under- or Over-Voltage Shutdown
DA9063L provides the capability to monitor the output voltage of internal regulators. In case of a
catastrophic failure, the related regulator is disabled. This feature is enabled using control
MON_MODE. Each internal regulator is assigned to a GPADC input channel and can be individually
enabled for monitoring via controls BCORE1_MON_EN to LDO11_MON_EN. For example, if ADC
channel A8 is connected to an enabled regulator and it is also enabled for monitoring, the ADC
automatically measures the regulator output voltage every 1 ms (10 ms in ADC economy mode).
Simultaneously, two relative thresholds are calculated from the regulator nominal output voltage
(supporting DVC). If the regulator is out of range, the voltage measurement is stored inside
MON_A8_RES, the regulator ID is recorded inside the index MON_A8_IDX and the event flag
E_REG_UVOV is set. To secure a stable output voltage, the monitoring is delayed after regulators
are switched on and when changing their voltage level to a new target (that is, during DVC slewing,
after writing into the active regulator voltage register, or when the active voltage control register is
changing between Vxxx_A and Vxxx_B). This delay is programmable using control UVOV_DELAY.
If debouncing is selected via MON_DEB, an event is only created if two consecutive measurements
exceed the same threshold. The feature is also available for channels A9 and A10.
Table 36: Assignment of Regulators for Voltage Monitoring
ADC channel
Regulator
Enable
A8
BUCKCORE1
BUCKCORE2
BUCKPRO
LDO3
LDO11
BCORE1_MON_EN
BCORE2_MON_EN
BPRO_MON_EN
LDO3_MON_EN
LDO11_MON_EN
A9
BUCKIO
BUCKMEM
BUCKPERI
BIO_MON_EN
BMEM_MON_EN
BPERI_MON_EN
A10
LDO7
LDO8
LDO9
LDO7_MON_EN
LDO8_MON_EN
LDO9_MON_EN
If more than one regulator is assigned to A8, A9, or A10, the regulator measurements are
sequentially multiplexed on this channel (elongates the measurement period of 1 ms or 10 ms by
each additional assigned regulator). In the case of an E_REG_UVOV event, the regulator monitoring
continues and shuts down rails facing catastrophic failure (voltage and IDX controls contain
information for determining the cause of the most recently detected under- or over-voltage). When
clearing E_REG_UVOV via a host write, the related regulator index controls are reset. In the unlikely
case in which several regulators from a sequenced ADC channel have triggered an under- or over-
voltage condition before the host was able to read the related controls, all monitored supplies may be
checked for their actual state (enabled or shutdown) to detect if further supplies have also been shut
down in addition to the one captured by the index control.
The assertion of nIRQ can be masked by IRQ mask M_REG_UVOV. With a masked nIRQ from
regulator supervision, the setting of MON_RES determines whether an out-of-range detection
disables the related regulator or triggers the assertion of port nRESET. In the latter case, nRESET is
asserted for 1 ms and continues to be asserted until the regulator returns to being in range
(regulators that are not enabled but are selected for monitoring do not trigger the assertion of
nRESET). With a masked nIRQ, GP_FB2 can be configured to flag PWR_OK, indicating that all
monitored regulator voltages are in-range. Selecting disabled regulators for monitoring suppresses
the assertion of PWR_OK.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com