Back Button XR88C192IP Datasheet HTML 18Page - Exar Corporation XR88C192IP Datasheet HTML 19Page - Exar Corporation XR88C192IP Datasheet HTML 20Page - Exar Corporation XR88C192IP Datasheet HTML 21Page - Exar Corporation XR88C192IP Datasheet HTML 22Page - Exar Corporation XR88C192IP Datasheet HTML 23Page - Exar Corporation XR88C192IP Datasheet HTML 24Page - Exar Corporation XR88C192IP Datasheet HTML 25Page - Exar Corporation XR88C192IP Datasheet HTML 26Page - Exar Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 32 page
background image
XR88C92/192
22
Rev. 1.31
START COUNTER/TIMER REGISTER (STCR)
-
Read Only
Reading from this register will start the C/T. Data values
returned should be ignored.
STOP COUNTER/TIMER REGISTER (SPCR) -
Read Only
Reading from this register will stop the C/T. Data values
returned should be ignored.
SET
OUTPUT
PORT
REGISTER
(SOPR) -
Write Only
Output ports (OP0-OP7), when used as general pur-
pose outputs, can be asserted (set to low) by writing a
“1” to the corresponding bit in this register. Once an
output is asserted, it can be negated only by issuing a
command through the Reset Output Port Register (see
below).
However, note that SOPR and ROPR cannot be used to
assert and negate outputs that are programmed for
alternate functions (see description under OPCR). For
example, if OP0 is programmed to output -RTSA (see
'Configuring Multi-purpose Outputs), it cannot be con-
trolled by SOPR or ROPR. In that case, commands from
the Command Register should be issued to assert (CRA
bits 7:4 = 0x8) and negate (CRA bits 7:4 = 0x9) OP0.
SOPR Bit 0-7:
0 = No change (same state).
1 = Assert the corresponding output (Set it low).
RESET OUTPUT PORT REGISTER (ROPR) - Write
Only
Each output port bit can be changed to high state by
writing a “1” to each individual bit.
ROPR Bit 0-7:
0 = No change (same state).
1 = Negate the corresponding output (Set it high).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com