| Electronic Components Datasheet Search |
|
CP10.241 Datasheet(PDF) 17 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP10.241 Datasheet(HTML) 17 Page - PULS GmbH |
|
17 / 30 page ![]() CP10.241, CP10.241-C1, CP10.241-S1, CP10.241-S2, CP10.242 CP-Series 24V, 10A, 240W, SINGLE PHASE INPUT Aug. 2017 / Rev. 1.4a DS-CP10.241-EN All values are typical at 24V, 10A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 17/30 17. PROTECTION FEATURES Output protection Electronically protected against overload, no-load and short-circuits. In case of a protection event, audible noise may occur. Output over-voltage protection Typ. 30.5Vdc Max. 32Vdc In case of an internal power supply defect, a redundant circuit limits the maximum output voltage. The output shuts down and automatically attempts to restart. Degree of protection IP 20 EN/IEC 60529 Penetration protection > 4mm E.g. screws, small parts Over-temperature protection Yes Output shut-down with automatic restart. The temperature sensor is installed on critical components inside the unit and turns the unit off in safety critical situations, which can happen e.g. when de-rating requirements are not observed, ambient temperature is too high, ventilation is obstructed or the de-rating requirements for different mounting orientation is not followed. There is no correlation between the operating temperature and turn-off temperature since this is dependent on input voltage, load and installation methods. Input transient protection MOV (Metal Oxide Varistor) For protection values see chapter 15 (EMC). Internal input fuse Included Not user replaceable slow-blow high-braking capacity fuse 18. SAFETY FEATURES Input / output separation Double or reinforced galvanic isolation SELV IEC/EN 60950-1 PELV IEC/EN 60204-1, EN 62477-1, IEC 60364-4-41 Class of protection I PE (Protective Earth) connection required Isolation resistance > 500MOhm At delivered condition between input and output, measured with 500Vdc > 500MOhm At delivered condition between input and PE, measured with 500Vdc > 500MOhm At delivered condition between output and PE, measured with 500Vdc > 500MOhm At delivered condition between output and DC-OK contacts, measured with 500Vdc PE resistance < 0.1Ohm Resistance between PE terminal and the housing in the area of the DIN-rail mounting bracket. Touch current (leakage current) Typ. 0.14mA / 0.36mA At 100Vac, 50Hz, TN-,TT-mains / IT-mains Typ. 0.20mA / 0.50mA At 120Vac, 60Hz, TN-,TT-mains / IT-mains Typ. 0.33mA / 0.86mA At 230Vac, 50Hz, TN-,TT-mains / IT-mains Max. 0.18mA / 0.43mA At 110Vac, 50Hz, TN-,TT-mains / IT-mains Max. 0.26mA / 0.61mA At 132Vac, 60Hz, TN-,TT-mains / IT-mains Max. 0.44mA / 1.05mA At 264Vac, 50Hz, TN-,TT-mains / IT-mains |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |