30 / 36 page ![]() REV. 0 –30– ADP3502 Table V. Registers ADDR Description D7 D6 D5 D4 D3 D2 D1 D0 Comments 00h Second Counter S5 S4 S3 S2 S1 S0 Note 1, 2 01h Minute Counter M5 M4 M3 M2 M1 M0 Note 1, 2 02h Hour Counter H4 H3 H2 H1 H0 Note 1, 2 03h Week Counter W2 W1 W0 Note 1, 2 04h Day Counter D4 D3 D2 D1 D0 Note 1, 2 05h Month Counter MO3 MO2 MO1 MO0 Note 1, 2 06h Year Counter Y6 Y5 Y4 Y3 Y2 Y1 Y0 Note 1, 2 07h Alarm A Minute AM5 AM4 AM3 AM2 AM1 AM0 Note 2 08h Alarm A Hour AH4 AH3 AH2 AH1 AH0 Note 2 09h Alarm A Week AW6 AW5 AW4 AW3 AW2 AW1 AW0 Note 2 0Ah Alarm B Minute BM5 BM4 BM3 BM2 BM1 BM0 Note 2 0Bh Alarm B Hour BH4 BH3 BH2 BH1 BH0 Note 2 0Ch Alarm B Week BW6 BW5 BW4 BW3 BW2 BW1 BW0 Note 2 0Dh Alarm Control ALA EN AOUT ALB EN BOUT Note 2 0Eh Periodic Interrupt Control PIC PI2 PI1 PI0 Note 2 0Fh Stay-Alive Timer Control CLR SA4 SA3 SA2 SA1 SA0 Note 2 10h Charger Control CHI CHEN Note 3 11h Charger MVBAT Control REF0 MVEN Note 3 12h Charger MVBAT CHV1 CHV0 MV4 MV3 MV2 MV1 MV0 Note 3 13h LDO Control 1 LDO11 LDO5 LDO4 Note 3 14h Not Available Note 4 15h LDO Control 2 SLEEP9 SLEEP7 LDO10 LDO9 LDO8 LDO7 Note 3 16h LDO Control 3 ALLOFF Note 3 17h LDO2 Gain G23 G22 G21 G20 Note 3 18h Keypad Column/LED BL KO3 KO2 KO1 KO0 Note 5 19h Keypad Row Input KI5 KI4 KI3 KI2 KI1 KI0 Note 5 1Ah GPIO Control GPC3 GPC2 GPC1 GPC0 Note 5 1Bh GPIO MASK GPMSK3 GPMSK2 GPMSK1 GPMSK0 Note 5 1Ch GPIO GPI3 GPI2 GPI1 GPIO Note 5 GPO3 GPO2 GPO1 GPO0 Note 5 1Dh GPIO INT GPINT3 GPINT2 GPINT1 GPINT0 Note 5, 6 GPRST3 GPRST2 GPRST1 GPRST0 Note 5, 6 1Eh INT INT6 INT5 INT4 INT3 INT2 INT1 INT0 Note 5, 6 IRST6 INT5 INT4 IRST3 IRST2 IRST1 IRST0 Note 5, 6 1Fh INT MASK MSK6 MSK5 MSK4 MSK3 MSK2 MSK1 MSK0 Note 5 20h DATA IN DI5 DI4 DI3 DI2 DI1 DI0 Note 5 21h Power OFF PWROFF Note 5 22h Power ON PWRON Note 5 3Fh TEST Register (Option) LDOENB USENB TEST Note 2, 7 NOTES 1. For RTC counter data protection, access should wait for a certain time period (62 µs) after the CS signal assertion. (Refer to the RTC Counter Operation section for the wait time). 2. Registers regarding the RTC counter. They are powered by RTCV. 3. Analog block control registers. They control LDO and so on. They are powered by VBAT. 4. Not available. 5. These are the registers for INT, GPIO, KEYPAD I/F, and so on. They are powered by VBAT. 6. The INT reset operation will be valid at 62 µs or later after it’s set. 7. This is a set register for an internal test and should not be accessed at normal operation. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |