| Electronic Components Datasheet Search |
|
S71GL064A Datasheet(PDF) 21 Page - SPANSION |
|
|
|||||||||||||||||||||||||||||
S71GL064A Datasheet(HTML) 21 Page - SPANSION |
|
21 / 134 page ![]() February 8, 2005 S71GL064A_00_A2 S71GL064A based MCPs 19 Advance Informatio n Device Bus Operations This section describes the requirements and use of the device bus operations, which are ini- tiated through the internal command register. The command register itself does not occupy any addressable memory location. The register is a latch used to store the commands, along with the address and data information needed to execute the command. The contents of the register serve as inputs to the internal state machine. The state machine outputs dictate the function of the device. Table 1 lists the device bus operations, the inputs and control levels they require, and the resulting output. The following subsections describe each of these op- erations in further detail. Table 1. Device Bus Operations Legend: L = Logic Low = VIL, H = Logic High = VIH, VID = 11.5–12.5 V, VHH = 11.5–12.5 V, X = Don’t Care, SA = Sector Address, AIN = Address In, DIN = Data In, DOUT = Data Out Notes: 1. Addresses are Amax:A0 in word mode; Amax:A-1 in byte mode. Sector addresses are Amax:A15 in both modes. 2. The sector protect and sector unprotect functions may also be implemented via programming equipment. See the “Sector Group Protection and Unprotection” section. 3. If WP# = VIL, the first or last sector remains protected (for uniform sector devices), and the two outer boot sectors are protected (for boot sector devices). If WP# = VIH, the first or last sector, or the two outer boot sectors will be protected or unprotected as determined by the method described in “Sector Group Protection and Unprotection”. All sectors are unprotected when shipped from the factory (The Secured Silicon Sector may be factory protected depending on version ordered.) 4. DIN or DOUT as required by command sequence, data polling, or sector protect algorithm (see Figure 2). Requirements for Reading Array Data To read array data from the outputs, the system must drive the CE# and OE# pins to VIL. CE# is the power control and selects the device. OE# is the output control and gates array data to the output pins. WE# should remain at VIH. The internal state machine is set for reading array data upon device power-up, or after a hard- ware reset. This ensures that no spurious alteration of the memory content occurs during the power transition. No command is necessary in this mode to obtain array data. Standard mi- croprocessor read cycles that assert valid addresses on the device address inputs produce Operation CE# OE# WE# RESET# WP# ACC Addresses (Note 1) DQ0–DQ15 Read L L H H X X AIN DOUT Write (Program/Erase) L H L H (Note 3) X AIN (Note 4) Accelerated Program L H L H (Note 3) VHH AIN (Note 4) Standby VCC ± 0.3 V X X VCC ± 0.3 V X H X High-Z Output Disable L H H H X X X High-Z Reset X X X L X X X High-Z Sector Group Protect (Note 2) L H L VID H X SA, A6 =L, A3=L, A2=L, A1=H, A0=L (Note 4) Sector Group Unprotect (Note 2) L H L VID H X SA, A6=H, A3=L, A2=L, A1=H, A0=L (Note 4) Temporary Sector Group Unprotect X X X VID H X AIN (Note 4) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |