13 / 20 page ![]() MP2319 – 18V, 3A, SYNCHRONOUS, STEP-DOWN CONVERTER MP2319 Rev.1.0 www.MonolithicPower.com 13 6/29/2016 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2016 MPS. All Rights Reserved. Light-load operation is also called skip mode because the HS-FET does not turn on as frequently as it does in heavy-load conditions. The frequency at which the HS-FET turns on is a function of the output current. As the output current increases, the time period that the current modulator regulates becomes shorter, and the HS-FET turns on more frequently. The switching frequency increases in turn. The output current reaches critical levels when the current modulator time is zero, and can be determined with Equation (1): IN OUT OUT OUT SW IN (V V ) V I 2 L F V (1) The device reverts to PWM mode once the output current exceeds the critical level. Afterward, the switching frequency remains fairly constant over the output current range. Enable (EN) EN is a digital control pin that turns the regulator on and off. Drive EN high to turn on the regulator; drive EN low to turn off the regulator. When floating, EN is pulled down to GND by an internal 1.1M Ω resistor. EN can be connected directly to VIN. EN supports an 18V input range. Under-Voltage Lockout (UVLO) Under-voltage lockout (UVLO) protects the chip from operating at an insufficient supply voltage. The MP2319 UVLO comparator monitors the output voltage of the internal regulator (VCC). The UVLO rising threshold is about 3.85V, while its falling threshold is 3.18V consistently. Internal Soft Start (SS) Soft start (SS) prevents the converter output voltage from overshooting during start-up. When the chip starts up, the internal circuitry generates a soft-start voltage (SS) that ramps up from 0V to 1.2V. When SS is lower than REF, SS overrides REF so the error amplifier uses SS as the reference. When SS exceeds REF, the error amplifier uses REF as the reference. The SS time is set to 0.8ms internally. Power Good (PG) Indicator The MP2319 uses a power good (PG) output to indicate whether the output voltage of the module is ready or not. PG is an open-drain output. Connect PG to VCC or another voltage source through a pull-up resistor (e.g.: 100kΩ). When input voltage is applied, PG is pulled down to GND before the internal VSS > 1V. After VSS > 1V, when VFB is above 91.5% of VREF, PG is pulled high after a 56µs delay. During normal operation, PG is pulled low when VFB drops below 81% of VREF after a 40µs delay. When UVLO or OTP occurs, PG is pulled low immediately. When over-current (OC) occurs, PG is pulled low when VFB drops below 81% of VREF after a 40µs delay. PG is pulled low to indicate output over-voltage when VFB rises above 122% of VREF after a 40µs delay. If VFB falls below 105% after over-voltage protection (OVP), PG is pulled high after a 56µs delay. Over-Current Protection (OCP) and Short- Circuit Protection (SCP) The MP2319 has a valley limit control. During the LS-FET on state, the inductor current is monitored. When the sensed inductor current reaches the valley current limit, the LS limit comparator (shown in Figure 1) turns over, and the MP2319 enters over-current protection (OCP) mode. The HS-FET waits until the inductor current falls below the valley current limit before turning on again. Meanwhile, the output voltage drops until VFB is below the under-voltage (UV) threshold, typically 50% below the reference. Once UV is triggered, the MP2319 enters hiccup mode to restart the part periodically. During OCP, the device attempts to recover from the over-current fault with hiccup mode. The MP2319 disables the output power stage, discharges the soft-start cap, and then tries to soft-start automatically. If the over-current condition still remains after the soft-start ends, the MP2319 repeats this operation cycle until the over-current condition is removed, and then the output rises back to regulation levels. OCP is a non-latch protection. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |