| Electronic Components Datasheet Search |
|
MP023GS Datasheet(PDF) 14 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP023GS Datasheet(HTML) 14 Page - Monolithic Power Systems |
|
14 / 23 page ![]() MP023 – PRIMARY-SIDE CC/CV CONTROLLER MP023 Rev. 1.1 www.MonolithicPower.com 14 7/18/2016 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2016 MPS. All Rights Reserved. VIPK fS VLimit-Max fS_L fS-min VLimit-Min fS_H Figure 5: Peak Current Modulation In the event that the external current sensing resistor is shorted, the maximum turn-on time is limited internally at tONmax. If this maximum limitation is reached, the IC enters protection mode. Constant Voltage (CV) Operation The MP023 detects the auxiliary winding voltage from FB and operates in constant voltage (CV) mode to regulate the output voltage. The auxiliary voltage can be calculated with Equation (5): aux aux O D s N V(V V ) N (5) Where VD is the forward drop voltage of the secondary diode. During the conduction time of the secondary diode, the difference between the output voltage and the voltage on the secondary winding is not constant since VD varies with the current flowing through the diode. To compensate for the voltage drop difference, the sampling time decreases gradually from tFBS-Max to tFBS-Min as the current limitation folds back from VLimit-Max to VLimit-Min (see Figure 6). Figure 6: FB Voltage Sampling Point The FB sampling time is also customizable with different resistor values connected to CS (see Figure 7). Please refer to EC table for details. Figure 7: External Resistor for Sampling Time Customization Choose a sampling time toward the end of the secondary diode conduction period to improve the accuracy of the CV regulation. The CV regulation loop then generates the switching frequency to regulate the output voltage based on the sampled voltage. Constant Current (CC) Operation Figure 8 shows the secondary current waveforms. Figure 8: Secondary Current Waveform In constant current (CC) operation, the CC loop control function remains at a fixed ratio between the secondary diode on time (tons) and the secondary diode off time (toffs) by charging or discharging the internal capacitance. The fixed ratio limits the maximum duty of the secondary side diode on time, as shown in Equation (6): ons SMax ons offs t D tt (6) For applications with varying output voltages, the DS-Max can be customized with CP. If CP is connected with a capacitor directly or shorted to GND, the DS-Max remains at a default value of 0.4. However, if CP is connected with a resistor (Figure 9), several choices are available based on the different resistances. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |