19 / 22 page ![]() MP174 – NON-ISOLATED OFF-LINE REGULATOR MP174 Rev. 1.01 www.MonolithicPower.com 19 8/18/2016 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2016 MPS. All Rights Reserved. FLOW CHART Power On Vcc>5.6V Internal High Voltage Regulator ON Y N Soft Start Monitor VFB Monitor Vcc OLP= Logic High Y OTP, SCP and open loop Monitor Y Vcc Decrease to 2.4V Shut Down Internal High Voltage Regulator N Continuous Fault Monitor Protection Logic High Y N UVLO, SCP, OLP, OTP and Open loop protections are auto restart Stop operation Y N Y VFB<2.55V VFB<1.7V Turn ON the MOSFET Y N 6144 switching counter finished? Vcc<3.4V Y Y N ? VFB<0.5V Y N Open loop Logic High Vcc < 5.3V Internal High Voltage Regulator ON Vcc > 5.6V N Shut Down Internal High Voltage Regulator Y N Figure 11: Control Flow Chart |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|