| Electronic Components Datasheet Search |
|
LT3965 Datasheet(PDF) 14 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LT3965 Datasheet(HTML) 14 Page - Linear Technology |
|
14 / 26 page ![]() LT3965/LT3965-1 14 39651fa For more information www.linear.com/LT3965 APPLICATIONS INFORMATION Table 3. Read-Only Fault Status Register (See All Channel Mode (ACMODE) Command section and Single Channel Mode (SCMODE) Command section for how to access these register bits). NAME B[7] B[6] B[5] B[4] B[3] B[2] B[1] B[0] DEFAULT OLFREG Open LED Status Bit for CH8 1: Fault 0: No Fault Open LED Status Bit for CH7 1: Fault 0: No Fault Open LED Status Bit for CH6 1: Fault 0: No Fault Open LED Status Bit for CH5 1: Fault 0: No Fault Open LED Status Bit for CH4 1: Fault 0: No Fault Open LED Status Bit for CH3 1: Fault 0: No Fault Open LED Status Bit for CH2 1: Fault 0: No Fault Open LED Status Bit for CH1 1: Fault 0: No Fault 00000000 SLFREG Shorted LED Status Bit for CH8 1: Fault 0: No Fault Shorted LED Status Bit for CH7 1: Fault 0: No Fault Shorted LED Status Bit for CH6 1: Fault 0: No Fault Shorted LED Status Bit for CH5 1: Fault 0: No Fault Shorted LED Status Bit for CH4 1: Fault 0: No Fault Shorted LED Status Bit for CH3 1: Fault 0: No Fault Shorted LED Status Bit for CH2 1: Fault 0: No Fault Shorted LED Status Bit for CH1 1: Fault 0: No Fault 00000000 Note: The LT3965/LT3965-1 sets all OLFREG and SLFREG register bits high and asserts the ALERT pin to indicate the overheat fault condition (≥170°C). (See LED/Overheat Fault Detection and Reporting section for detail.) The LT3965/LT3965-1 indicates that the part is in shutdown state by setting all OLFREG and SLFREG register bits high and deasserting the ALERT pin. S O A TO CONTROL CHANNEL SWITCH O = A IF S = 0 O = B IF S = 1 O = A IF S = 00 O = B IF S = 01 O = C IF S = 10 O = D IF S = 11 S = 0 IF POR OR ACMREG IS WRITTEN S = 1 IF SCMREG1 IS WRITTEN B S 2 O LED CONSTANT OFF LED CONSTANT ON LED DWOFT LED DWFT DWOFT: DIMMING WITHOUT FADE TRANSITION DWFT: DIMMING WITH FADE TRANSITION DWOFT: DIMMING WITHOUT FADE TRANSITION DWFT: DIMMING WITH FADE TRANSITION A B C D DIMMING CONTROL CHANNEL COUNTER CHANNEL LED FAULT DETECTOR CHANNEL COMPARATOR 2 8 2 2 2 11 CLK TO CH2 DRN1 LEDREF SRC1 OPEN LED FAULT TO SET OLFREG B[0] SCMREG1 (LT3965 POR DEFAULT: 11 00 01 00000001; LT3965-1 POR DEFAULT: 01 00 00 00000001) SCMREG8 (LT3965 POR DEFAULT: 11 00 01 00000001; LT3965-1 POR DEFAULT: 01 00 00 00000001) SHORTED LED FAULT TO SET SLFREG B[0] POR DV[7:0] VSTH[1:0] MC[1:0] VOTH[1:0] B[7]-B[0] CH1 CH2 ↓ CH7 B[11:10] B[9:8] B[13:12] S O A TO CONTROL CHANNEL SWITCH O = A IF S = 0 O = B IF S = 1 O = A IF S = 00 O = B IF S = 01 O = C IF S = 10 O = D IF S = 11 S = 0 IF POR OR ACMREG IS WRITTEN S = 1 IF SCMREG8 IS WRITTEN B S 2 O LED CONSTANT OFF LED CONSTANT ON LED DWOFT LED DWFT A B C D DIMMING CONTROL CHANNEL COUNTER CHANNEL LED FAULT DETECTOR CHANNEL COMPARATOR 2 8 2 2 2 11 CLK DRN8 LEDREF SRC8 OPEN LED FAULT TO SET OLFREG B[7] SHORTED LED FAULT TO SET SLFREG B[7] POR DV[7:0] 3965 F05 VSTH[1:0] MC[1:0] VOTH[1:0] B[7]-B[0] CH8 B[11:10] B[9:8] B[13:12] • • • • • • TO CH3 TO CH4 TO CH5 TO CH6 TO CH7 Figure 5. LT3965/LT3965-1 Command Registers and Channel Control Diagram |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |