  LTM4650EY Datasheet HTML 1Page - Linear Technology LTM4650EY Datasheet HTML 2Page - Linear Technology LTM4650EY Datasheet HTML 3Page - Linear Technology LTM4650EY Datasheet HTML 4Page - Linear Technology LTM4650EY Datasheet HTML 5Page - Linear Technology LTM4650EY Datasheet HTML 6Page - Linear Technology LTM4650EY Datasheet HTML 7Page - Linear Technology LTM4650EY Datasheet HTML 8Page - Linear Technology  
Zoom Inzoom in Zoom Outzoom out
 2 / 8 page
background image
2
dc2479aaf
DEMO MANUAL DC2479A-A
QUICK START PROCEDURE
Demonstration circuit DC2479A-A is easy to set up to
evaluate the performance of the LTM4650EY. Please refer
to Figure 1 for proper measurement setup and follow the
procedure below:
1. With power off, connect the input power supply, load
and meters as shown in Figure 2. Preset the load to 0A
and VIN supply to 12V.
2. Turn on the power supply at the input. The output volt-
age should be 1.0V ± 1.5% (0.985V~1.015V).
3. Oncetheproperoutputvoltageisestablished,adjustthe
load within the operating range and observe the output
voltage regulation, output voltage ripple, efficiency and
other parameters. Output ripple can be measured at J6
with BNC cables.
4. (Optional) For optional load transient test, apply an
adjustable pulse signal between “IOSTEP CLK” and
“GND” test point. Pulse amplitude (3V~3.5V) sets the
loadstepcurrentamplitude.Theoutputtransientcurrent
can be monitored at the BNC connector J5 (10mV/A).
The pulse signal should have very small duty cycle
(< 10%) to limit the thermal stress on the transient
load circuit.
PERFORMANCE SUMMARY Specifications are at T
A = 25°C
PARAMETER
CONDITIONS/NOTES
VALUE
Input Voltage Range
4.5V ~ 15V
Output Voltage VOUT
VIN = 4.5~15V, IOUT = 0~50A
1.0V ± 1.5% (0.985V ~ 1.015V)
Maximum Continuous Output Current
De-Rating is Necessary for Certain VIN, VOUT and Thermal Conditions,
See Data Sheet for Detail.
50A
Default Operating Frequency
500kHz
Efficiency
VIN = 12V, VOUT = 1.0V, IOUT = 50A, fSW = 500 kHz
86.6%, See Figure 4
Load Transient
VIN = 12V, VOUT = 1.0V, ISTEP = 25A to 37.5A
< 60mVP-P, See Figure 5



Html Pages

1 2 3 4 5 6 7 8


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com