20 / 40 page ![]() LTC3858-2 20 38582f APPLICATIONS INFORMATION CIN and COUT Selection The selection of CIN is simplified by the 2-phase architec- ture and its impact on the worst-case RMS current drawn through the input network (battery/fuse/capacitor). It can be shown that the worst-case capacitor RMS current occurs when only one controller is operating. The controller with the highest (VOUT)(IOUT) product needs to be used in the formula shown in Equation 1 to determine the maximum RMS capacitor current requirement. Increasing the out- put current drawn from the other controller will actually decrease the input RMS ripple current from its maximum value. The out-of-phase technique typically reduces the input capacitor’s RMS ripple current by a factor of 30% to 70% when compared to a single phase power supply solution. In continuous mode, the source current of the top MOSFET is a square wave of duty cycle (VOUT)/(VIN). To prevent large voltage transients, a low ESR capacitor sized for the maximum RMS current of one channel must be used. The maximum RMS capacitor current is given by: CIN Required IRMS ≈ IMAX VIN VOUT () VIN –VOUT () ⎡⎣ ⎤⎦ 1/ 2 (1) Equation 1 has a maximum at VIN = 2VOUT, where IRMS = IOUT/2. This simple worst-case condition is commonly used for design because even significant deviations do not offer much relief. Note that capacitor manufacturers’ ripple current ratings are often based on only 2000 hours of life. This makes it advisable to further derate the capacitor, or to choose a capacitor rated at a higher temperature than required. Several capacitors may be paralleled to meet size or height requirements in the design. Due to the high operating frequency of the LTC3858-2, ceramic capacitors can also be used for CIN. Always consult the manufacturer if there is any question. The benefit of 2-phase operation can be calculated by using Equation 1 for the higher power controller and then calculating the loss that would have resulted if both controller channels switched on at the same time. The total RMS power lost is lower when both controllers are operating due to the reduced overlap of current pulses required through the input capacitor’s ESR. This is why the input capacitor’s requirement calculated above for the worst-case controller is adequate for the dual controller design. Also, the input protection fuse resistance, battery resistance, and PC board trace resistance losses are also reduced due to the reduced peak currents in a 2-phase system. The overall benefit of a multiphase design will only be fully realized when the source impedance of the power supply/battery is included in the efficiency testing. The drains of the top MOSFETs should be placed within 1cm of each other and share a common CIN (s). Separat- ing the sources and CIN may produce undesirable voltage and current resonances at VIN. A small (0.1μF to 1μF) bypass capacitor between the chip VIN pin and ground, placed close to the LTC3858-2, is also suggested. A small (1Ω to 10Ω) resistor placed between CIN (C1) and the VIN pin provides further isolation between the two channels. The selection of COUT is driven by the effective series resistance (ESR). Typically, once the ESR requirement is satisfied, the capacitance is adequate for filtering. The output ripple (ΔVOUT) is approximated by: ΔVOUT ≈ΔIL ESR + 1 8• f • COUT ⎛ ⎝ ⎜ ⎞ ⎠ ⎟ where fO is the operating frequency, COUT is the output capacitance and ΔIL is the ripple current in the inductor. The output ripple is highest at maximum input voltage since ΔIL increases with input voltage. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |