16 / 22 page ![]() LTC3874-1 16 38741f For more information www.linear.com/LTC3874-1 applicaTions inForMaTion If the external clock frequency is greater than the inter- nal oscillator’s frequency, fOSC, then current is sourced continuously from the phase detector output, pulling up the filter network. When the external clock frequency is less than fOSC, current is sunk continuously, pulling down the filter network. If the external and internal frequencies are the same but exhibit a phase difference, the current sources turn on for an amount of time corresponding to the phase difference. The voltage on the filter network is adjusted until the phase and frequency of the internal and external oscillators are identical. At the stable operating point, the phase detector output is high impedance and the filter capacitor holds the voltage. Typically, the external clock (on the SYNC pin) input high threshold is 2V, while the input low threshold is 1.4V. Fault Protection and Response Master controllers monitor system voltage, current, tem- perature and provide many protection features during all kinds of fault conditions. The LTC3874-1 slave control- lers do not provide as many fault protections as master controllers but respond to the fault signal from the master controller. FAULT0 and FAULT1 pins are designed to share the fault signal between masters and slaves. In a typical parallel application, connect the fault pins on LTC3874-1 to the master fault indictor pins, so that the slave control- ler can respond to all fault signals from the master. When the FAULT pin is pulled below 1.4V, the PWM pin in the corresponding channel is in three-state. When the FAULT pin voltage is above 2V, the corresponding channel is back to normal operation. During fault conditions, all internal circuits in the LTC3874-1 are still running so the slave controllers can immediately return to normal operation when the FAULT pin is released. The LTC3874-1 has internal thermal shutdown protection which forces the PWM pin three-state when the junction temperature is higher than 160°C. The thermal shutdown has 10°C of hysteresis. In thermal shutdown, the FAULT0 and FAULT1 pins are also pulled low. The RUN pins are not internally pulled low. There is a 500k pull-down resistor on each FAULT pin which sets the default voltage on the FAULT pins low if the FAULT pins are floating. Transient Response and Loop Stability In a typical parallel operation, the LTC3874-1 cooperates with master controllers to supply more current. To achieve balanced current sharing between master and slave, it is recommended that each slave channel copies the power stage design from the master channel. Select the same inductors, same MOSFET driver, same power MOSFETs, and same output capacitors between the master and slave channels. Control loop and compensation design on the ITH pin should start with the single phase operation of the master controller. The multiphase transient response and loop stability is almost the same as the single phase opera- tion of the master by tying the ITH pins together between master and slaves. For example, design the compensation for a single phase 1.8V/20A output using LTC3884-1 with a 0.33μH inductor and 530μF output capacitors. To extend the output to 1.8V/40A, simply parallel one channel of LTC3874-1 with the same inductor and output capacitors (total output capacitors are 1060μF) and tie the ITH pin of LTC3874-1tothemasterITH.Theloopstabilityandtransient responses of the two phase converter are very similar to the single phase design without any extra compensator on the ITH pin of the slave controller. Furthermore, LTpow- erCAD is provided on the LTC website as a free download for transient and stability analysis. To minimize the high frequency noise on the ITH trace between master and slave ITH pins, a small filter capacitor in the range of tens of pF can be placed closely at each ITH pin of the slave controller. This small capacitor normally does not significantly affect the closed-loop bandwidth but increases the gain margin at high frequency. Mode Selection and Pre-Biased Startup There may be situations that require the power supply to start up with a pre-bias on the output capacitors. In this case, it is desirable to start up without discharging the output capacitors. The LTC3874-1 can be configured to operate in DCM mode for pre-biased start-up. The master chip’s PGOOD pin can be connected to the MODE pins of the LTC3874-1 to ensure the DCM operation at startup and CCM operation in steady state. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |