Back Button HSP50214BVCZ Datasheet HTML 44Page - Renesas Technology Corp HSP50214BVCZ Datasheet HTML 45Page - Renesas Technology Corp HSP50214BVCZ Datasheet HTML 46Page - Renesas Technology Corp HSP50214BVCZ Datasheet HTML 47Page - Renesas Technology Corp HSP50214BVCZ Datasheet HTML 48Page - Renesas Technology Corp HSP50214BVCZ Datasheet HTML 49Page - Renesas Technology Corp HSP50214BVCZ Datasheet HTML 50Page - Renesas Technology Corp HSP50214BVCZ Datasheet HTML 51Page - Renesas Technology Corp HSP50214BVCZ Datasheet HTML 52Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 48 / 62 page
background image
HSP50214B
FN4450 Rev 4.00
Page 48 of 62
May 1, 2007
CONTROL WORD 1: INPUT LEVEL DETECTOR (SYNCHRONOUS TO CLKIN)
BIT
POSITION
FUNCTION
DESCRIPTION
31
Reserved
Reserved.
30
Integration Mode
0- Integration of magnitude error stops when the interval counter times out.
1- Integration runs continuously. When the interval counter times out, the integrator reloads, and the
results of the integration is sent to a register for the processor to read.
29-14
Integration Interval
These are the top 16-bits of the 18-bit integration counter, ICPrel. ICPrel = (N)/4+1; where N is the
desired integration period in CLKIN cycles, defined as the number of input samples to be integrated. N
must be a multiple of 4: [0, 4, 8, 12, 16.... , 218]. Bit 29 is the MSB. If the input is interpolated, then the
zeros must be accounted for, as they will be added to the threshold! If the gated input mode is used, the
same input sample will be accumulated multiple times.
13-0
Input Threshold
Input Magnitude Threshold. Bits 12-0 correspond to input bits 12-0. The magnitude of the input is added
to this threshold, where the threshold is a signed number. Bit 13 is the MSB.
CONTROL WORD 2: INPUT LEVEL DETECTOR START STROBE (SYNCHRONIZED TO CLKIN)
BIT
POSITION
FUNCTION
DESCRIPTION
N/A
Start Input Level
Detector AGC
Integrator
Writing to this location starts/restarts the input AGC error integrator. The integrator will either restart or
stop when the integration interval counter times out depending on bit 30 of Control Register 1 (see
Microprocessor Write Section).
CONTROL WORD 3: CARRIER NCO CENTER FREQUENCY (SYNCHRONIZED TO CLKIN)
BIT
POSITION
FUNCTION
DESCRIPTION
31-0
Carrier Center
Frequency
These bits control the frequency of the Carrier NCO. The frequency range of the NCO is
 fS/2 where
fS is the input sample rate. The bits are computed by the equation N = (FNCO / fS)*232. Bit 31 is the MSB.
This location is a holding register. After loading, a transfer to the active register is done by writing to
Control Word 5 or by generating a SYNCIN1 with Control Word 0, Bit 20 set to 1. The Carrier NCO only
updates ENI is active.
NOTE: In the HSP50214B, if the SYNCIN1 occurs when the NCO is not updating, the load signal is held internal to the part until the next NCO
update.
CONTROL WORD 4: CARRIER PHASE OFFSET (SYNCHRONIZED TO CLKIN)
BIT
POSITION
FUNCTION
DESCRIPTION
31-10
Reserved
Reserved.
9-0
Carrier Phase Offset
These bits, PO, are used to offset the phase of the carrier NCO. The bits are computed by the Equation
PO = INT[(210
off)/2]HEX; (-<off<) for 10-bit 2’s complement representation or from 0 to 2 for 10-
bit offset binary representation. Bit 9 is the MSB. This location is a holding register. After loading, a
transfer to the active register is done by writing to Control Word 6 or by generating a SYNCIN1 with
Control Word 0, Bit 20 set to 1. The carrier NCO only updates when ENI is active.
CONTROL WORD 5: CARRIER FREQUENCY STROBE (SYNCHRONIZED TO CLKIN)
BIT
POSITION
FUNCTION
DESCRIPTION
N/A
Carrier Frequency
Strobe
Writing to this address updates the carrier frequency Control Word from the Holding Register.
CONTROL WORD 6: CARRIER PHASE STROBE (SYNCHRONIZED TO CLKIN)
BIT
POSITION
FUNCTION
DESCRIPTION
N/A
Carrier Phase Strobe
Writing to this address updates the carrier phase offset Control Word with the value written to the phase
offset (PO) register.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com