| Electronic Components Datasheet Search |
|
RCM500 Datasheet(PDF) 13 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
RCM500 Datasheet(HTML) 13 Page - Bel Fuse Inc. |
|
13 / 17 page ![]() tech.support@psbel.com belfuse.com/power-solutions BCD.00803 Rev AC, 10-May-2018 Page 13 of 17 RCM Series 500 / 1000 W DC-DC Converters © 2018 Bel Power Solutions & Protection Immunity to Environmental Conditions Table 6: Mechanical and climatic stress. Air pressure 800 – 1200 hPa Test method Standard Test Conditions Status Ad Low temperature start-up test EN 50155:2017, clause 13.4.4 IEC/EN 60068-2-1 Temperature, duration: - 40 °C, 2 h Not operating Performance test: +25 °C Be Dry heat test, cycle A EN 50155:2017, clause 13.4.5 IEC/EN 60068-2-2 Temperature: 70 °C Operating perf. crit. A Duration: 6 h Db 2 Cyclic damp heat test EN 50155:2017, clause 13.4.7 IEC/EN 60068-2-30 Temperature: 55 °C and 25 °C Not operating Cycles(respirationeffect): 2 Duration: 2x 24 h Ka Salt mist test sodium chloride (NaCl) solution EN 50155:2017, clause 12.2.10 IEC/EN 60068-2-11 class ST3 Temperature: 35 ±2 °C Converter not operating Duration: 28 h Functional random vibration test EN 50155:2017 clause 13.4.11.4 EN 61373:2010 clause 8, class B, body mounted 1 Acceleration amplitude: 0.1 g n = 1.01 m/s 2 Operating perf. crit. A Frequency band: 5 – 150 Hz Test duration: 30 min (10 min in each axis) Simulated long life testing EN 50155:2017 clause 13.4.11.2 EN 61373:2010 clause 9, class B, body mounted 1 Acceleration amplitude: 0.58 g n = 5.72 m/s 2 Not operating Frequency band: 5 – 150 Hz Test duration: 15 h (5 h in each axis) Shock test EN 50155:2017 clause 13.4.11.3 EN 61373:2010 clause 10, class B, body mounted 1 Acceleration amplitude: 5.1 g n Operating perf. crit. A Bump duration: 30 ms Number of bumps: 18 (3 in each direction) Vibration sinusoidal AREMA Part. 11.5.1 class C, D, E, I, J Acceleration amplitude: 0.3” (5 – 20 Hz) 1.5 g n = 14.7 m/s 2 Operating perf. crit. A Frequency: 10 – 200 Hz Test duration: 12 h (4 h in each axis) Mechanical shock AREMA Part. 11.5.1 class C, D, E, I, J Acceleration amplitude: 10 g n = 98 m/s 2 Operating perf. crit. A Bump duration: 11 ms Number of bumps: 18 (3 in each direction) 1 Body mounted = chassis of a railway coach Temperatures Table 7: Temperature specifications, valid for an air pressure of 800 – 1200 hPa (800 – 1200 mbar) Model RCM500 RCM1000 Unit EN 50155:2017 Class OT4 EN 50155:2017 Class OT2 Characteristics Conditions min max 10 min min max 10 min T A Ambient temperature Converter operating - 40 70 85 - 40 55 2 70 °C T C Case temperature 1 - 40 90 90 T S Storage temperature Not operational - 55 85 - 55 85 1 Measured at the measurement point T C ; see Mechanical Data. 2 RCM1000 can be operated at higher temperature with reduced output power. Reliability Table 8: MTBF and device hours Ratings at specified case temperature between failures Model MTBF Demonstrated hours 1 Accord. to IEC 62380 110RCM500-24DMQF 1 120 000 h 110RCM1000-24DMQF 1 110 000 h 1 Statisticalvalues,baseduponanaverageof4300workinghoursperyearandingeneralfielduseover5years; upgrades and customer-induced errors are excluded. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |