X3100 Datasheet(PDF) 13 Page - Renesas Technology Corp

Part # X3100
Description  3 or 4 Cell Li-ion Battery Protection and Monitor IC
PDF  40 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  RENESAS [Renesas Technology Corp]
Direct Link  http://www.renesas.com
Logo RENESAS - Renesas Technology Corp

X3100 Datasheet(HTML) 13 Page - Renesas Technology Corp

Back Button X3100 Datasheet HTML 9Page - Renesas Technology Corp X3100 Datasheet HTML 10Page - Renesas Technology Corp X3100 Datasheet HTML 11Page - Renesas Technology Corp X3100 Datasheet HTML 12Page - Renesas Technology Corp X3100 Datasheet HTML 13Page - Renesas Technology Corp X3100 Datasheet HTML 14Page - Renesas Technology Corp X3100 Datasheet HTML 15Page - Renesas Technology Corp X3100 Datasheet HTML 16Page - Renesas Technology Corp X3100 Datasheet HTML 17Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 40 page
background image
X3100, X3101
FN8110 Rev 1.00
Page 13 of 40
January 3, 2008
Bit 1 of the status register simply indicates whether or
not the X3100 or X3101 is in over-discharge protection
mode.
Bit 2 of the status register (CCES+OVDS) indicates the
status of two conditions of the X3100 or X3101. Cell
Charge Enable Status (CCES) is an internally generated
signal which indicates the status of any cell voltage
(VCELL) with respect to the Cell Charge Enable Voltage
(VCE). Over-charge Voltage Detection Status (OVDS) is
an internally generated signal which indicates whether
or not the X3100 or X3101 is in over-charge protection
mode.
When the cell charge enable function is switched ON
(configuration bit SWCEN=0), the signals CCES and
OVDS are logically OR’ed (CCES+OVDS) and written to
bit 2 of the status register. If the cell charge enable func-
tion is switched OFF (configuration bit SWCEN=1), then
bit 2 of the status register effectively only represents infor-
mation about the over-charge status (OVDS) of the
X3100 or X3101 (See Table 18, Table 17 and Figure ).
Table 18. Status Register Functionality.
Notes: † This bit is set in the configuration register.
X3100/X3101 INTERNAL PROTECTION FUNCTIONS
The X3100 and the X3101 provide periodic monitoring
(see section “Periodic Protection Monitoring” on page
13) for over-charge and over-discharge states and con-
tinuous monitoring for an over-current state. It has auto-
matic shutdown when a protection mode is encountered,
as well as automatic return after the device is released
from a protection mode. When sampling voltages
through the analog port (Monitor Mode), over-charge
and over-discharge protection monitoring is also per-
formed on a continuous basis.
Voltage thresholds for each of these protection modes
(VOV, VUV, and VOC respectively) can be individually
selected via software and stored in an internal non-vola-
tile register. This feature allows the user to avoid the
restrictions of mask programmed voltage thresholds, and
is especially useful during prototype/evaluation design
stages or when cells with slightly different characteristics
are used in an existing design.
Delay times for the detection of, and release from protec-
tion modes (TOV, TUV/TUVR, and TOC/TOCR respectively)
can be individually varied by setting the values of exter-
nal capacitors connected to pins OVT, UVT, OCT.
Periodic Protection Monitoring
In normal operation, the analog select pins are set such
that AS2 = L, AS1 = L, AS0 = L. In this mode the X3100
and X3101 conserve power by sampling the cells for
over or over-discharge conditions.
In this state over-charge and over-discharge protection
circuitry are usually off, but are periodically switched on
by the internal Protection Sample Rate Timer (PSRT). The
over-charge and over-discharge protection circuitry is on
for approximately 2ms in each 125ms period. Over-cur-
rent monitoring is continuous. In monitor mode (see
page 21) over-charge and over-discharge monitoring is
also continuous.
Bit(s)
Name
Description
Case
Status
Interpretation
0
VRGS+OCDS Voltage regulator
status
+
Over-current
detection status
-1
VRGO not yet tuned (VRGO = 5V ± 10%) OR
X3100/X3101 in over-current protection mode.
0VRGO tuned (VRGO = 5V ± 0.5%) AND
X3100/X3101 NOT in over-current protection mode.
1
UVDS
Over-discharge
detection status
-
1
X3100/X3101 in over-discharge protection mode
0
X3100/X3101 NOT in over-discharge protection mode
2
CCES+OVDS
Cell charge
enable status
+
Over-charge
detection status
SWCEN =0†
1VCELL < VCE OR
X3100/X3101 in over-charge protection mode
0VCELL > VCE AND
X3100/X3101 NOT in over-charge protection mode
SWCEN =1†
1
X3100/X3101 in over-charge protection mode
0
X3100/X3101 NOT in over-charge protection mode
3 - 7
-
-
0
Not used (always return zero)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com