| Electronic Components Datasheet Search |
|
EM6420 Datasheet(PDF) 36 Page - EM Microelectronic - MARIN SA |
|
|
|||||||||||||||||||||||||||||
EM6420 Datasheet(HTML) 36 Page - EM Microelectronic - MARIN SA |
|
36 / 54 page ![]() EM6420 Copyright 2012, EM Microelectronic-Marin SA 6420-DS.doc, Version 4.0 , 4-Jun-12 36 www.emmicroelectronic.com 8.3.14 Command setThreshold This command sets the initial sensor activation threshold. 7 0 1 7 0 2 1 1 1 0 0 1 0 E5 H 1 Threshold Figure 8-23 : setThreshold command format Threshold values must be in the range from 3 to 200. Invalid values will cause the EM6420 to assert its IRQ output and return error code 04H. The default threshold value is 6 10. The threshold value can only be defined before the Touch Screen interface is started. Attempting to modify that value while the Touch Screen interface is already running will cause the EM6420 to assert its IRQ output and return error code 06H. 8.3.15 Command getAppSettings This command gets the current application settings, i.e. the current Touch Screen scan frequency and the current highest scanned sensor number. 7 0 1 7 0 2 1 1 1 0 1 0 0 E8 H 0 CSF U CHSN ( CSF SHL 4 ) # CHSN Figure 8-24 : getAppSettings command format Valid values for parameter CHSN range from 0 to 15, thus indicating a number of scanned sensors comprised between 1 and 16. Note that the current sensor number could also be unknown, if it hasn’t been specified by the host processor and the Touch Screen has not been started yet. In that case, the flag U is set, and CHSN contains the highest possible sensor number, depending on the scan frequency, i.e.15 at scan frequencies up to 32 Hz, 7 at 64 Hz and 3 at 128 Hz. Table 8-15 lists valid values for parameter CSF. Note that a 64 Hz or 128 Hz scan frequency can only be obtained with a reduced number of sensors, i.e. 8 at 64 Hz and 4 at 128 Hz. Table 8-15 : Current Touch Screen scan frequency 8.3.16 Command getVersion This command gets the hardware as well as the software version of the EM6420. 10 Please contact EM Microelectronic-Marin SA to change the default threshold value CSF Touch Screen scan frequency CSF Touch Screen scan frequency 000B 1 Hz 100B 16 Hz 001B 2 Hz 101B 32 Hz 010B 4 Hz 110B 64 Hz 011B 8 Hz 111B 128 Hz |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |