| Electronic Components Datasheet Search |
|
EM8500 Datasheet(PDF) 15 Page - EM Microelectronic - MARIN SA |
|
|
|||||||||||||||||||||||||||||
EM8500 Datasheet(HTML) 15 Page - EM Microelectronic - MARIN SA |
|
15 / 34 page ![]() EM8500 Copyright 2017, EM Microelectronic-Marin SA 8500-DS, Version 2.1, 24-May-17 15 www.emmicroelectronic.com 420005-A01, 2.0 Register name: reg_hrv_check_lvl Address: 0x05 Default value mapped in E2PROM Bits Bit name Type Description 7:4 – – Reserved 3:0 hrv_check_lvl RW Minimum HRV short-cut current level to generate energy. Ihrv_check = (hrv_check_lvl+1) * 1µA if IHRV < Ihrv_check and reg_v_hrv_cfg.hrv_check_vld = '0' then reg_status.hrv_low = '1' Table 5-5 Minimum HRV short-cut current (0x05) When LTS and STS are not connected internally (in “primary cell mode” or in “battery protection mode”) the DCDC booster is able to deliver up to around 1mW maximum to the application. This value depends on input (VDD_HRV) and output (VDD_STS) voltages. 5.2.3. TIMING CONFIGURATION In addition to voltage level supervision, the user can select independent values for the frequency of supervision on LTS, STS and the harvester. The frequency influences the overall EM8500 power consumption and therefore its efficiency. The STS and LTS measurement periods are set through the registers reg_t_sts_period and reg_t_lts_period. The monitoring of the harvester however requires stopping the DCDC pumping process for a short time to measure the open voltage (in case the VLD is used) or the short-cut current (in case the current level detector is used). The duration of the DCDC disable period is configured through the reg_t_hrv_meas register, whereas the measurement period is configured through the reg_t_hrv_period register. VDD_HRV t_hrv_period t_hrv_meas t Harvester open voltage MPPT target voltage sampling Regulation running Figure 5-1 DCDC Regulation Timings Register value t_hrv_meas t_hrv_period t_sts_period t_lts_period t_hrv_low_period t_lts_hrv_low_period 0x00 16 ms 256 ms 1 ms 1 ms 256 ms 2 ms 0x01 32 ms 512 ms 2 ms 4 ms 512 ms 8 ms 0x02 64 ms 1 s 8 ms 16 ms 1 s 32 ms 0x03 128 ms 2 s 16 ms 64 ms 2 s 128 ms 0x04 256 ms 4 s 32 ms 256 ms 4 s 512 ms 0x05 512 ms 8 s 64 ms 1 s 8 s 2 s 0x06 1 s 16 s 128 ms 4 s 16 s 8 s 0x07 2 s 32 s 256 ms 16 s 32 s 32 s Table 5-6 Timing Configuration When entering in “HRV low mode” the monitoring on LTS and the harvester remains active, however the monitoring frequency can be adapted to this situation where the system cannot take energy anymore from the harvester source. The measurement period is then set in parameter t_hrv_low_period. In this mode STS is not fed by the harvester anymore. If STS and LTS are not connected internally, STS will collapse. No monitoring is performed on STS. When the harvester is monitored (reg_v_hrv_cfg.hrv_check_vld) based on the voltage measurement, the sampling value is set at the same frequency as the harvester voltage check. However, if the current level detector is used, the measurement of the current is done alternatively with the MPPT target setting, dividing by 2 the effective frequency of measurement and setting. For example if Thrv_period is set to 4 s, the period for checking the harvester voltage is 8 s, as well as the one for the MPPT target setting, and the harvester current checking is done 4 s after the MPPT target setting. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |