Back Button EM8500 Datasheet HTML 11Page - EM Microelectronic - MARIN SA EM8500 Datasheet HTML 12Page - EM Microelectronic - MARIN SA EM8500 Datasheet HTML 13Page - EM Microelectronic - MARIN SA EM8500 Datasheet HTML 14Page - EM Microelectronic - MARIN SA EM8500 Datasheet HTML 15Page - EM Microelectronic - MARIN SA EM8500 Datasheet HTML 16Page - EM Microelectronic - MARIN SA EM8500 Datasheet HTML 17Page - EM Microelectronic - MARIN SA EM8500 Datasheet HTML 18Page - EM Microelectronic - MARIN SA EM8500 Datasheet HTML 19Page - EM Microelectronic - MARIN SA Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 34 page
background image
EM8500
Copyright
2017, EM Microelectronic-Marin SA
8500-DS, Version 2.1, 24-May-17
15
www.emmicroelectronic.com
420005-A01, 2.0
Register name: reg_hrv_check_lvl
Address: 0x05
Default value mapped in E2PROM
Bits
Bit name
Type
Description
7:4
–
–
Reserved
3:0
hrv_check_lvl
RW
Minimum HRV short-cut current level to generate energy.
Ihrv_check = (hrv_check_lvl+1) * 1µA
if IHRV < Ihrv_check and reg_v_hrv_cfg.hrv_check_vld = '0' then reg_status.hrv_low = '1'
Table 5-5 Minimum HRV short-cut current (0x05)
When LTS and STS are not connected internally
(in “primary cell mode” or in “battery protection mode”) the DCDC booster is able to deliver up to
around 1mW maximum to the application. This value depends on input (VDD_HRV) and output (VDD_STS) voltages.
5.2.3.
TIMING CONFIGURATION
In addition to voltage level supervision, the user can select independent values for the frequency of supervision on LTS, STS and the harvester.
The frequency influences the overall EM8500 power consumption and therefore its efficiency.
The STS and LTS measurement periods are set through the registers reg_t_sts_period and reg_t_lts_period. The monitoring of the harvester
however requires stopping the DCDC pumping process for a short time to measure the open voltage (in case the VLD is used) or the short-cut
current (in case the current level detector is used). The duration of the DCDC disable period is configured through the reg_t_hrv_meas register,
whereas the measurement period is configured through the reg_t_hrv_period register.
VDD_HRV
t_hrv_period
t_hrv_meas
t
Harvester open voltage
MPPT target voltage
sampling
Regulation running
Figure 5-1 DCDC Regulation Timings
Register value
t_hrv_meas
t_hrv_period
t_sts_period
t_lts_period
t_hrv_low_period
t_lts_hrv_low_period
0x00
16 ms
256 ms
1 ms
1 ms
256 ms
2 ms
0x01
32 ms
512 ms
2 ms
4 ms
512 ms
8 ms
0x02
64 ms
1 s
8 ms
16 ms
1 s
32 ms
0x03
128 ms
2 s
16 ms
64 ms
2 s
128 ms
0x04
256 ms
4 s
32 ms
256 ms
4 s
512 ms
0x05
512 ms
8 s
64 ms
1 s
8 s
2 s
0x06
1 s
16 s
128 ms
4 s
16 s
8 s
0x07
2 s
32 s
256 ms
16 s
32 s
32 s
Table 5-6 Timing Configuration
When entering in
“HRV low mode” the monitoring on LTS and the harvester remains active, however the monitoring frequency can be adapted to
this situation where the system cannot take energy anymore from the harvester source. The measurement period is then set in parameter
t_hrv_low_period. In this mode STS is not fed by the harvester anymore. If STS and LTS are not connected internally, STS will collapse. No
monitoring is performed on STS.
When the harvester is monitored (reg_v_hrv_cfg.hrv_check_vld) based on the voltage measurement, the sampling value is set at the same
frequency as the harvester voltage check. However, if the current level detector is used, the measurement of the current is done alternatively with
the MPPT target setting, dividing by 2 the effective frequency of measurement and setting. For example if Thrv_period is set to 4 s, the period for
checking the harvester voltage is 8 s, as well as the one for the MPPT target setting, and the harvester current checking is done 4 s after the
MPPT target setting.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com