Part # OV-24DC
Description  Solid-State Relays
PDF  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  PHOENIX [PHOENIX CONTACT]
Direct Link  http://www.phoenixcontact.com
Logo PHOENIX - PHOENIX CONTACT

OV-24DC Datasheet(HTML) 2 Page - PHOENIX CONTACT

  OV-24DC Datasheet HTML 1Page - PHOENIX CONTACT OV-24DC Datasheet HTML 2Page - PHOENIX CONTACT OV-24DC Datasheet HTML 3Page - PHOENIX CONTACT OV-24DC Datasheet HTML 4Page - PHOENIX CONTACT  
Zoom Inzoom in Zoom Outzoom out
 2 / 4 page
background image
OV-24DC …
103082_01_en
PHOENIX CONTACT
2
Ordering Data
Technical Data
Solid-State Relays With DC Voltage Output
Description
Type
Order No.
Pcs./Pck.
Solid-state relay, for signal amplification and electrical isolation of the control
and load circuits, can be plugged into the SIM-AMS plug-in base, which can
be soldered, or mounted directly on the PCB with PCB connection,
input/output: DC voltage (350 V DC, maximum)
OV-24DC/350DC/1
2982634
10
Solid-state relay, for signal amplification and electrical isolation of the control
and load circuits, can be plugged into the SIM-AMS plug-in base, which can
be soldered, or mounted directly on the PCB with PCB connection,
input/output: DC voltage (60 V DC, maximum)
OV-24DC/ 60DC/4
2982647
10
Solid-State Relays With AC Voltage Output
Description
Type
Order No.
Pcs./Pck.
Solid-state relay, for signal amplification and electrical isolation of the control
and load circuits, can be plugged into the SIM-AMS plug-in base, which can
be soldered, or mounted directly on the PCB with PCB connection,
input: DC voltage/output: AC voltage
OV-24DC/480AC/5
2982650
10
Accessories
Description
Type
Order No.
Pcs./Pck.
Plug-in base
SIM-AMS ...
See INTERFACE catalog
Input Data
...350DC/1
...60DC/4
...480AC/5
Nominal input voltage UN
24 V DC
24 V DC
24 V DC
Operating voltage range
4.25 V DC ... 32 V DC
4 V DC ... 32 V DC
Voltage switching threshold
"0" signal
"1" signal
< 1 V DC
> 3.3 V DC
< 1 V DC
> 3.3 V DC
< 1.2 V DC
> 3.5 V DC
Typical input current at UN
15 mA
15 mA
10 mA
Typical switch-on time
< 100
µs
< 100
µs
1/2 period, maximum
Typical switch-off time
< 250
µs
< 250
µs
1/2 period, maximum
Switching frequency for ohmic nominal load
100 Hz
100 Hz
25 Hz
Output Data
...350DC/1
...60DC/4
...480AC/5
Nominal output voltage range
1 V DC ... 350 V DC
1 V DC ... 60 V DC
12 V AC ... 530 V AC
Periodic peak reverse voltage
–
–
1000 V
Limiting continuous current (see derating curves)
1 A
4 A
5 A
Minimum load current
1 mA
1 mA
20 mA
Surge current
20 A (tp = 1 s)
25 A (tp = 1 s)
80 A (tp = 20 ms)
Voltage drop at maximum limiting continuous current (2-wire)
0.5 V
0.5 V
1.2 V
Maximum load value I2t–
–
50 A2s
Leakage current when switched off
100
µA
100
µA
1 mA
Maximum phase shift (inductive loads)
–
–
cos
ϕ = ≥ 0.5
Protective circuit
Diode for protection
against polarity reversal
Diode for protection
against polarity reversal
–



Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com