| Electronic Components Datasheet Search |
|
P7SA-10F Datasheet(PDF) 14 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
P7SA-10F Datasheet(HTML) 14 Page - Omron Electronics LLC |
|
14 / 16 page ![]() G7SA 14 <Using with back-connecting sockets, PCB terminal sockets (P7SA-10P, P7SA-14P)> Refer to Common Precautions for All Relays with Forcibly Guided Contacts at the following URL: http://www.ia.omron.com/. 5-1-3. Soldering of Terminals 5-2. PCB Relays 5-3. Common Items Push-In Plus Terminal Sockets (P7SA- @F-ND-PU) 1. Connecting Wires to the Push-In Plus Terminal Block Part Names of the Terminal Block Connecting Wires with Ferrules and Solid Wires Insert the solid wire or ferrule straight into the terminal block until the end strikes the terminal block. • If a wire is difficult to connect because it is too thin, use a flat-blade screwdriver in the same way as when connecting stranded wire. Connecting Stranded Wires Use the following procedure to connect the wires to the terminal block. 1. Hold a flat-blade screwdriver at an angle and insert it into the release hole. The angle should be between 10° and 15°. If the flat-blade screwdriver is inserted correctly, you will feel the spring in the release hole. 2. With the flat-blade screwdriver still inserted into the release hole, insert the wire into the terminal hole until the end strikes the terminal block. 3. Remove the flat-blade screwdriver from the release hole. Checking Connections • After the insertion, pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal block. • If you use a ferrule with a conductor length of 10 mm, part of the conductor may be visible after the ferrule is inserted into the terminal block, but the product insulation distance will still be satisfied. 2. Removing Wires from the Push-In Plus Terminal Block Use the following procedure to remove wires from the terminal block. The same method is used to remove stranded wires, solid wires, and ferrules. 1. Hold a flat-blade screwdriver at an angle and insert it into the release hole. 2. With the flat-blade screwdriver still inserted into the release hole, remove the wire from the terminal insertion hole. 3. Remove the flat-blade screwdriver from the release hole. 3. Recommended Ferrules and Crimp Tools Recommended ferrules Note: 1. Make sure that the outer diameter of the wire coating is smaller than the inner diameter of the insulation sleeve of the recommended ferrule. 2. Make sure that the ferrule processing dimensions conform to the following figures. Recommended Flat-blade Screwdriver Use a flat-blade screwdriver to connect and remove wires. Use the following flat-blade screwdriver. The following table shows manufacturers and models as of 2015/Dec. * OMRON's exclusive purchase model XW4Z-00B is available to order as SZF 0-0,4×2,5 (manufactured by Phoenix Contact). Release hole Terminal (insertion) hole Release hole Terminal (insertion) hole Ferrules or solid wires 1 3 2 2 Flat-blade screwdriver 10 to15° 1 3 Stranded wires Applicable wire Ferrule Conductor Length (mm) Stripping length (mm) (Ferrules used) Recommended ferrules (mm2) (AWG) Phoenix Contact product Weidmuller product Wago product 0.5 20 8 10 AI 0,5-8 H0.5/14 216-201 10 12 AI 0,5-10 H0.5/16 216-241 0.75 18 8 10 AI 0,75-8 H0.75/14 216-202 10 12 AI 0,75-10 H0.75/16 216-242 1/1.25 18/17 8 10 AI 1-8 H1.0/14 216-203 10 12 AI 1-10 H1.0/16 216-243 1.25/1.5 17/16 8 10 AI 1,5-8 H1.5/14 216-204 10 12 AI 1,5-10 H1.5/16 216-244 Recommended crimp tool CRIMPFOX6 CRIMPFOX6T-F CRIMPFOX10S PZ6 roto Variocrimp4 Model Manufacturer SZS 0,4×2,5 SZF 0-0,4×2,5 * Phoenix Contact ESD 0,40×2,5 Wera 0.4×2.5×75 302 Wiha AEF.2,5×75 Facom 210-719 Wago SDI 0.4×2.5×75 Weidmuller 1 3 2 2 10 to 15° Wire Flat-blade screwdriver 1 3 8 to 10 mm 1.9 mm max. 2.6 mm max. Side 0.4 mm 2.5 mm dia. 2.5 mm Front |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |