| Electronic Components Datasheet Search |
|
AK4331 Datasheet(PDF) 71 Page - Asahi Kasei Microsystems |
|
|
|||||||||||||||||||||||||||||
AK4331 Datasheet(HTML) 71 Page - Asahi Kasei Microsystems |
|
71 / 91 page ![]() [AK4331] 018006903-E-00 2018/07 - 71 - 9-20. Serial Control Interface (I 2C-bus) The AK4331 supports the fast-mode I 2C-bus (Max: 400 kHz). Pull-up resistors at the SDA and SCL pins must be connected to (TVDD + 0.3) V or less voltage. 1. WRITE Operation Figure 34 shows the data transfer sequence for the I 2C-bus mode. All commands are preceded by a START condition. A HIGH to LOW transition on the SDA line while SCL is HIGH indicates a START condition (Figure 40). After the START condition, a slave address is sent. This address is 7 bits long followed by the eighth bit that is a data direction bit (R/W). The most significant seven bits of the slave address are fixed as “0010000”. If the slave address matches that of the AK4331, the AK4331 generates an acknowledge and the operation is executed. The master must generate the acknowledge-related clock pulse and release the SDA line (HIGH) during the acknowledge clock pulse (Figure 41). A R/W bit value of “1” indicates that the read operation is to be executed, and “0” indicates that the write operation is to be executed. The second byte consists of the control register address of the AK4331. The format is MSB first 8 bits (Figure 36). The data after the second byte contains control data. The format is MSB first, 8 bits (Figure 37). The AK4331 generates an acknowledge after each byte is received. Data transfer is always terminated by a STOP condition generated by the master. A LOW to HIGH transition on the SDA line while SCL is HIGH defines a STOP condition (Figure 40). The AK4331 can perform more than one byte write operation per sequence at address from 00H to 17H. After receipt of the third byte the AK4331 generates an acknowledge and awaits the next data. The master can transmit more than one byte instead of terminating the write cycle after the first data byte is transferred. After receiving each data packet the internal address counter is incremented by one, and the next data is automatically taken into the next address. If the address exceeds 17H prior to generating a stop condition, the address counter will “roll over” to 00H and the previous data will be overwritten. The data on the SDA line must remain stable during the HIGH period of the clock. HIGH or LOW state of the data line can only be changed when the clock signal on the SCL line is LOW (Figure 42) except for the START and STOP conditions. SDA Slave Address S S T A R T R/W = "0" A C K Sub Address(n) A C K Data(n) A C K Data(n+ 1) A C K A C K Data(n+ x) A C K P S T O P Figure 34. Data Transfer Sequence in I 2C-bus Mode |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |