13 / 27 page ![]() MLX75306 3 rd Generation Linear Optical Array 390107530601 Page 13 of 27 Data Sheet Rev. 003 Aug/12 To start an integration cycle, an SI(L) command including the required integration time has to be uploaded. The SI command is defined in Table 6, while the SIL command is defined in Table 7. The integration time is defined by the uploaded integration time T[15..0] and the frequency of the RC oscillator and can be calculated as follows: For SI command: RCO f T t 4 ] 0 .. 15 [ int − = For SIL command: RCO f T t 11 16 ] 0 .. 15 [ int + = A time tfr after finishing an integration cycle, the FrameReady pin goes high, indicating that a read-out com- mand can be uploaded. A read-out command will not be accepted as long as the FrameReady pin is low. A timing diagram is shown in Figure 4. The time tfr can be calculated as (see Figure 4): RCO CLK fr t t t _ int β + = with β between 21 and 22 tCLK_RCO, due to synchronization between the SCLK and the RCO clock domain. As the CS pin controls the tri-state condition of the MISO output, the MISO pin is driven during upload of a SI command. However the output data which appears on MISO is invalid and must be ignored. CS SCLK MOSI MISO Tri state Tri state FrameReady SI Command t fr Figure 4: Timing diagram for Integration phase When the first command byte is recognized as an integration command and CS is disabled (high), the inte- gration phase will start after maximum 3 tCLK_RCO due to the synchronization between the SCLK and RCO clock domain. This allows the user to define/delay the start of integration and to avoid any noise caused by SPI switching. 9.2.4 ROx – Read-Out Command (x bit) After an integration cycle has been completed and the FrameReady pin is high, a Read-Out Command as defined in Table 8 can be uploaded. A timing diagram for the RO Command is given in Figure 5. Control1 Byte Control2 Byte Control3 Byte 1001 X3X2X1X0 S7S6S5S4 S3S2S1S0 E7E6E5E4 E3E2E1E0 ADC resolution X3X2X1X0 = 1100 X3X2X1X0 = 0110 1-bit ADC resolution 1.5-(2) bit ADC resolution |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |