Back Button AMC1035 Datasheet HTML 8Page - Texas Instruments AMC1035 Datasheet HTML 9Page - Texas Instruments AMC1035 Datasheet HTML 10Page - Texas Instruments AMC1035 Datasheet HTML 11Page - Texas Instruments AMC1035 Datasheet HTML 12Page - Texas Instruments AMC1035 Datasheet HTML 13Page - Texas Instruments AMC1035 Datasheet HTML 14Page - Texas Instruments AMC1035 Datasheet HTML 15Page - Texas Instruments AMC1035 Datasheet HTML 16Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 22 page
background image
DOUT
(MCE = 0)
CLKIN
VCMov G sCM G sCMuv
VCMuv < VCM < VCMov
VCM
DOUT
(MCE = 1)
CLKIN
DOUT
(MCE = 0)
(VINP t VINN) ” t1.25 V
(VINP t VINN) • 1.25 V
...
...
...
...
...
...
127 CLKIN cycles
127 CLKIN cycles
DOUT
(MCE = 0)
...
DOUT
(MCE = 1)
DOUT
(MCE = 1)
...
...
...
12
AMC1035
SBAS837 – AUGUST 2018
www.ti.com
Product Folder Links: AMC1035
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
7.4 Device Functional Modes
The AMC1035 is operational when the power supply VDD and clock signal CLKIN are applied, as specified in the
Recommended Operating Conditions and Switching Characteristics tables.
7.4.1 Output Behavior in Case of a Full-Scale Input
If a full-scale input signal is applied to the AMC1035 (that is, VIN ≥ VClipping), the device generates a single one or
zero every 128 bits at DOUT, as shown in Figure 7, depending on the actual polarity of the signal being sensed.
This feature is also supported with Manchester-coded output and allows full-scale and invalid input signals to be
identified as described in the Fail-Safe Output section and can be used for advanced system-level diagnostics.
Figure 7. Overrange Output of the AMC1035
7.4.2 Fail-Safe Output
Figure 8 shows that if the common-mode voltage of the input reaches or exceeds the specified common-mode
undervoltage, VCMuv, or overvoltage detection level, VCMov as defined in the Electrical Characteristics table, the
DOUT of the AMC1035 is held at steady-state high.
Figure 8. Fail-Safe Output of the AMC1035



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com