| Electronic Components Datasheet Search |
|
MAX8632 Datasheet(PDF) 13 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX8632 Datasheet(HTML) 13 Page - Maxim Integrated Products |
|
13 / 29 page ![]() The on-time one-shot has good accuracy at the operat- ing points specified in the Electrical Characteristics table (approximately ±12.5% at 600kHz and 450kHz, and ±10% at 200kHz and 300kHz). On-times at operat- ing points far removed from the conditions specified in the Electrical Characteristics table can vary over a wider range. For example, the 600kHz setting typically runs approximately 10% slower with inputs much greater than 5V due to the very short on-times required. The constant on-time translates only roughly to a con- stant switching frequency. The on-times guaranteed in the Electrical Characteristics table are influenced by resistive losses and by switching delays in the high- side MOSFET. Resistive losses, which include the inductor, both MOSFETs, the output capacitor’s ESR, and any PC board copper losses in the output and ground, tend to raise the switching frequency as the load increases. The dead-time effect increases the effective on-time, reducing the switching frequency as one or both dead times are added to the effective on- time. The dead time occurs only in PWM mode (SKIP = VDD) and during dynamic output-voltage transitions when the inductor current reverses at light or negative load currents. With reversed inductor current, the induc- tor’s EMF causes LX to go high earlier than normal, extending the on-time by a period equal to the DH-rising dead time. For loads above the critical conduction point, where the dead-time effect is no longer a factor, the actual switching frequency is: where VDROP1 is the sum of the parasitic voltage drops in the inductor discharge path, including the synchro- nous rectifier, the inductor, and any PC board resis- tances; VDROP2 is the sum of the resistances in the charging path, including the high-side switch (Q1 in the Typical Applications Circuit of Figure 8), the inductor, and any PC board resistances, and tON is the one-shot on-time (see the On-Time One-Shot (TON) section. Automatic Pulse-Skipping Mode (SKIP = GND) In skip mode (SKIP = GND), an inherent automatic switchover to PFM takes place at light loads (Figure 2). This switchover is affected by a comparator that trun- cates the low-side switch on-time at the inductor cur- rent’s zero crossing. The zero-crossing comparator differentially senses the inductor current across the synchronous-rectifier MOSFET (Q2 in the Typical Applications Circuit of Figure 8). Once VPGND - VLX drops below 5% of the current-limit threshold (2.5mV for the default 50mV current-limit threshold), the com- parator forces DL low (Figure 1). This mechanism caus- es the threshold between pulse-skipping PFM and nonskipping PWM operation to coincide with the boundary between continuous and discontinuous inductor-current operation (also known as the critical conduction point). The load-current level at which PFM/PWM crossover occurs, ILOAD(SKIP), is equal to half the peak-to-peak ripple current, which is a function of the inductor value (Figure 2). This threshold is rela- tively constant, with only a minor dependence on the input voltage (VIN): where K is the on-time scale factor (see Table 1). For example, in the Typical Applications Circuit of Figure 8 (K = 1.7µs, VOUT = 2.5V, VIN = 12V, and L = 1µH), the pulse-skipping switchover occurs at: The crossover point occurs at an even lower value if a swinging (soft-saturation) inductor is used. The switching waveforms can appear noisy and asynchronous when light loading causes pulse-skipping operation, but this is a normal operating condition that results in high light- load efficiency. Trade-offs in PFM noise vs. light-load efficiency are made by varying the inductor value. Generally, low inductor values produce a broader effi- ciency vs. load curve, while higher values result in higher full-load efficiency (assuming that the coil resistance 25 17 21 12 2 12 168 . . . Vs H V V A × × ⎛ ⎝⎜ ⎞ ⎠⎟ ⎛ ⎝⎜ ⎞ ⎠⎟ = µ µ - .5V I VK L VV V LOAD SKIP OUT IN OUT IN () = × ⎛ ⎝⎜ ⎞ ⎠⎟ ⎛ ⎝⎜ ⎞ ⎠⎟ 2 - f VV tV V SW OUT DROP ON IN DROP = + + () 1 2 Integrated DDR Power-Supply Solution for Desktops, Notebooks, and Graphic Cards ______________________________________________________________________________________ 13 Table 1. Approximate K-Factor Errors TON SETTING TYPICAL K-FACTOR (µs) K-FACTOR ERROR (%) MINIMUM VIN AT VOUT = 2.5V (h = 1.5; SEE THE DROPOUT PERFORMANCE (BUCK) SECTION) 200 (TON = AVDD) 5.0 ±10 3.15 300 (TON = open) 3.3 ±10 3.47 450 (TON = REF) 2.2 ±12.5 4.13 600 (TON = GND) 1.7 ±12.5 5.61 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |