| Electronic Components Datasheet Search |
|
BMC050 Datasheet(PDF) 74 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMC050 Datasheet(HTML) 74 Page - Bosch Sensortec GmbH |
|
74 / 105 page ![]() Datasheet BMC050 Electronic Compass Page 74 Confidential BST-BMC050-DS000-10 | Revision 1.0 | October 2011 Bosch Sensortec © Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are subject to change without notice. Not intended for publication. Register (0x4C) contains control bits for operation mode, output data rate and self-test. The two “Adv. ST” bits control the on-chip advanced self-test (see chapter 4.5.2 for details of the magnetometer advanced self-test). The three “Data rate” bits control the magnetometer output data rate according to below Table 85. The two “Opmode” bits control the operation mode according to below Table 86 (see chapter 4.3.2 for a detailed description of magnetometer power modes). Table 84: Operation mode, output data rate and self-test control register (0x4C) (0x4C) Bit Name Description Bit 7 Adv. ST <1> Advanced self-test control bit 1 Bit 6 Adv. ST <0> Advanced self-test control bit 0 Bit 5 Data rate <2> Data rate control bit 2 Bit 4 Data rate <1> Data rate control bit 1 Bit 3 Data rate <0> Data rate control bit 0 Bit 2 Opmode <1> Operation mode control bit 1 Bit 1 Opmode <0> Operation mode control bit 0 Bit 0 Self Test Normal self-test control bit Three “Data rate” bits control the output data rate (ODR) of the BMC050 magnetometer part: Table 85: Output data rate (ODR) setting (0x4C) (0x4C) Data rate <2:0> Magnetometer output data rate (ODR) 000b 10 (default) 001b 2 010b 6 011b 8 100b 15 101b 20 110b 25 111b 30 Two “Data rate” bits control the operation mode of the BMC050 magnetometer part: Table 86: Operation mode setting (0x4C) (0x4C) Opmode <1:0> Magnetometer operation mode4 00b Normal mode 01b Forced mode 10b Reserved, do not use 11b Sleep Mode 4 See chapter 4.3.2 for a detailed description of magnetometer power modes. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |