Back Button BMI055 Datasheet HTML 30Page - Bosch Sensortec GmbH BMI055 Datasheet HTML 31Page - Bosch Sensortec GmbH BMI055 Datasheet HTML 32Page - Bosch Sensortec GmbH BMI055 Datasheet HTML 33Page - Bosch Sensortec GmbH BMI055 Datasheet HTML 34Page - Bosch Sensortec GmbH BMI055 Datasheet HTML 35Page - Bosch Sensortec GmbH BMI055 Datasheet HTML 36Page - Bosch Sensortec GmbH BMI055 Datasheet HTML 37Page - Bosch Sensortec GmbH BMI055 Datasheet HTML 38Page - Bosch Sensortec GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 34 / 149 page
background image
BMI055
Data sheet
Page 34
BST-BMI055-DS000-08 | Revision 1.2 | July 2014
Bosch Sensortec
©Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third
parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are preliminary and subject to change without notice.
The threshold is defined through register (ACC 0x28) slope_th. In terms of scaling 1 LSB of
(ACC 0x28) slope_th corresponds to 3.91 mg in 2g-range (7.81 mg in 4g-range, 15.6 mg in 8g-
range and 31.3 mg in 16g-range). Therefore the maximum value is 996 mg in 2g-range (1.99g
in 4g-range, 3.98g in 8g-range and 7.97g in 16g-range).
The time difference between the successive acceleration signals depends on the selected
bandwidth and equates to 1/(2*bandwidth) (t=1/(2*bw)). In order to suppress false triggers, the
interrupt is only generated (cleared) if a certain number N of consecutive slope data points is
larger (smaller) than the slope threshold given by (ACC 0x28) slope_th. This number is set by
the (ACC 0x27) slope_dur bits. It is N = (ACC 0x27) slope_dur + 1 for (ACC 0x27).
Example: (ACC 0x27) slope_dur = 00b, …, 11b = 1decimal, …, 4decimal.
5.6.5.1 Enabling (disabling) for each axis
Any-motion detection can be enabled (disabled) for each axis separately by writing ´1´ (´0´) to
bits (ACC 0x16) slope_en_x, (ACC 0x16) slope_en_y, (ACC 0x16) slope_en_z. The criteria for
any-motion detection are fulfilled and the slope interrupt is generated if the slope of any of the
enabled axes exceeds the threshold (ACC 0x28) slope_th for [(ACC 0x27) slope_dur +1]
consecutive times. As soon as the slopes of all enabled axes fall or stay below this threshold for
[(ACC 0x27) slope_dur +1] consecutive times the interrupt is cleared unless interrupt signal is
latched.
5.6.5.2 Axis and sign information of slope / any motion interrupt
The interrupt status is stored in bit (ACC 0x09) slope_int. The any-motion interrupt supplies
additional information about the detected slope. The axis which triggered the interrupt is given
by that one of bits (ACC 0x0B) slope_first_x, (ACC 0x0B) slope_first_y, (ACC 0x0B)
slope_first_z that contains a value of ´1´. The sign of the triggering slope is held in bit (ACC
0x0B) slope_sign until the interrupt is retriggered. If (ACC 0x0B) slope_sign = ´0´ (´1´), the sign
is positive (negative).
5.6.5.3 Tap sensing
Tap sensing has a functional similarity with a common laptop touch-pad or clicking keys of a
computer mouse. A tap event is detected if a pre-defined slope of the acceleration of at least
one axis is exceeded. Two different tap events are distinguished: A ‘single tap’ is a single event
within a certain time, followed by a certain quiet time. A ‘double tap’ consists of a first such
event followed by a second event within a defined time frame.
Single tap interrupt is enabled (disabled) by writing ´1´ (´0´) to bit (ACC 0x16) s_tap_en. Double
tap interrupt is enabled (disabled) by writing ´1´ (´0´) to bit (ACC 0x16) d_tap_en.
The status of the single tap interrupt is stored in bit (ACC 0x09) s_tap_int, the status of the
double tap interrupt is stored in bit (ACC 0x09) d_tap_int.
The slope threshold for detecting a tap event is set by bits (ACC 0x2B) tap_th. The meaning of
(ACC 0x2B) tap_th depends on the range setting. 1 LSB of (ACC 0x2B) tap_th corresponds to
a slope of 62.5mg in 2g-range, 125mg in 4g-range, 250mg in 8g-range, and 500mg in 16g-
range.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com