| Electronic Components Datasheet Search |
|
TDA8954TH Datasheet(PDF) 13 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDA8954TH Datasheet(HTML) 13 Page - NXP Semiconductors |
|
13 / 46 page ![]() TDA8954_1 © NXP B.V. 2009. All rights reserved. Product data sheet Rev. 01 — 24 December 2009 13 of 46 NXP Semiconductors TDA8954 2 × 210 W class-D power amplifier 8.4.3 Window Protection (WP) Window Protection (WP) checks the conditions at the output terminals of the power stage and is activated: • During the start-up sequence, when the TDA8954 is switching from Standby to Mute. Start-up will be interrupted if a short-circuit is detected between one of the output terminals and one of the supply pins. The TDA8954 will wait until the short-circuit to the supply lines has been removed before resuming start-up. The short circuit will not generate large currents because the short-circuit check is carried out before the power stages are enabled. • When the amplifier is shut down completely because the OCP circuit has detected a short circuit to one of the supply lines. WP will be activated when the amplifier attempts to restart after 100 ms (see Section 8.4.2). The amplifier will not start-up again until the short circuit to the supply lines has been removed. 8.4.4 Supply voltage protection If the supply voltage drops below the minimum supply voltage threshold, Vth(uvp), the UVP circuit will be activated and the system will shut down. Once the supply voltage rises above Vth(uvp) again, the system will restart after a delay of 100 ms. If the supply voltage exceeds the maximum supply voltage threshold, Vth(ovp), the OVP circuit will be activated and the power stages will be shut down. When the supply voltage drops below Vth(ovp) again, the system will restart after a delay of 100 ms. An additional UnBalance Protection (UBP) circuit compares the positive analog supply voltage (on pin VDDA) with the negative analog supply voltage (on pin VSSA) and is triggered if the voltage difference exceeds a factor of two (VDDA > 2 × |VSSA| OR |VSSA| > 2 × V DDA). When the supply voltage difference drops below the unbalance threshold, Vth(ubp), the system restarts after 100 ms. Fig 9. Current limiting VDIAG2 IMAX IOUT current limiting short circuit protection short to VDDP applied t switch off amplifier 010aaa563 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |