| Electronic Components Datasheet Search |
|
EM5301GE Datasheet(PDF) 9 Page - Excelliance MOS Corp. |
|
|
|||||||||||||||||||||||||||||
EM5301GE Datasheet(HTML) 9 Page - Excelliance MOS Corp. |
|
9 / 13 page ![]() 2013/04/22 Rev.A.5 9 EM5301 Functional Description EM5301 is a voltage mode synchronous buck PWM controller. This device provides complete protection function such as over current protection, under voltage protection and over voltage protection. Supply Voltage The VCC pin provides the bias supply of EM5301 control circuit, as well as lower MOSFET’s gate and the BOOT voltage for the upper MOSFET’s gate. A minimum 0.1uF ceramic capacitor is recommended to bypass the supply voltage. Power ON Reset To let EM5301 start to operation, VCC voltage must be higher than its POR voltage even when REFIN voltage is pulled higher than enable high voltage. Typical POR voltage is 4.0V. Shutdown The COMP/SD pin can be used to enable or disable EM5301. Pull down COMP/SD pin below 0.2V can disable the controller. Soft Start EM5301 provides soft start function internally. The FB voltage will track the internal soft start signal, which ramps up from zero during soft start period. OCP, Over Current Protection The over current function protects the converter from a shorted output by using lower MOSFET’s on-resistance to monitor the current. The OCP level can be calculated as the following equation: DS(ON) OCP OCP R V I − = When OCP is triggered, EM5301 will shut down the converter and cycles the soft start function in a hiccup mode. If over current condition still exist after 3 times of hiccup, EM5301 will shut down the controller and latch. UVP, Under Voltage Protection The FB voltage is monitored for under voltage protection. The UVP threshold is typical 0.6V. When UVP is triggered, EM5301 will shut down the converter and cycles the soft start function in a hiccup mode. OVP, Over Voltage Protection The FB voltage is monitored for over voltage protection. The OVP threshold is typical 1.04V. When OVP is triggered, EM5301 will turn off upper MOSFET and turn on lower MOSFET. Feedback Compensation Fig.1 shows the voltage mode control loop for a synchronous-rectified buck converter. The compensation network consists of the error amplifier and the impedance networks ZIN and ZFB. The goal of the compensation network is to provide a closed loop transfer function with adequate phase margin. OSC Lo VOUT Co ESR VIN PHASE DRIVER PWM COMPARATOR VOSC ZI ZFB REFERENCE ERROR AMP DRIVER VOUT ZIN ZFB REFERENCE FB COMP C1 R2 C2 C3 R3 R1 Fig.1 Compensation for Voltage Mode Buck Converter |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |