Electronic Components Datasheet Search
  English  ▼

X  

24LC16B Datasheet(PDF) 5 Page - ARTSCHIP ELECTRONICS CO.,LMITED.

Part # 24LC16B
Description  Serial EEPROM
PDF  19 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  ARTSCHIP [ARTSCHIP ELECTRONICS CO.,LMITED.]
Direct Link  http://www.artschip.com/
Logo ARTSCHIP - ARTSCHIP ELECTRONICS CO.,LMITED.

24LC16B Datasheet(HTML) 5 Page - ARTSCHIP ELECTRONICS CO.,LMITED.

  24LC16B Datasheet HTML 1Page - ARTSCHIP ELECTRONICS CO.,LMITED. 24LC16B Datasheet HTML 2Page - ARTSCHIP ELECTRONICS CO.,LMITED. 24LC16B Datasheet HTML 3Page - ARTSCHIP ELECTRONICS CO.,LMITED. 24LC16B Datasheet HTML 4Page - ARTSCHIP ELECTRONICS CO.,LMITED. 24LC16B Datasheet HTML 5Page - ARTSCHIP ELECTRONICS CO.,LMITED. 24LC16B Datasheet HTML 6Page - ARTSCHIP ELECTRONICS CO.,LMITED. 24LC16B Datasheet HTML 7Page - ARTSCHIP ELECTRONICS CO.,LMITED. 24LC16B Datasheet HTML 8Page - ARTSCHIP ELECTRONICS CO.,LMITED. 24LC16B Datasheet HTML 9Page - ARTSCHIP ELECTRONICS CO.,LMITED. Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 19 page
background image
24LC16B
www.artschip.com
5
2.0
FUNCTINOAL DESCRIPTION
The 24XX16 supports a bidirectional, 2-wire bus and data
transmission protocol. A device that sends data onto the bus is
defined as transmitter, while a device receiving data is defined
as a receiver. The bus has to be controlled by a master device
which generates the Serial Clock (SCL), controls the bus access
and generates the Start and Stop conditions, while the 24XX16
works as slave. Both master and slave can operate as
transmitter or receiver, but the master device determines which
mode is activated.
3.0
BUS CHARACTERISTICS
The following bus protocol has been defined:
Data transfer may be initiated only when the bus is not busy.
During data transfer, the data line must remain stable
whenever the clock line is high. Changes in the data line while
the clock line is high will be interpreted as a Start or Stop
condition.
Accordingly, the following bus conditions have been defined
(Figure 3-1).
3.1
Bus Not Busy (A)
Both data and clock lines remain high.
3.2
Start Data Transfer (B)
A high–to–low transition of the SDA line while the clock (SCL) is
high determines a Start condition. All commands must be
preceded by a Start condition.
3.3
Stop Data Transfer (C)
A low-to-high transition of the SDA line while the clock (SCL) is
high determines a Stop condition. All operations must be ended
with a Stop condition.
3.4
Data Valid (D)
The state of the data line represents valid data when, after a
Start condition, the data line is stable for the duration of the high
period of the clock signal.
The data on the line must be changed during the low period of
the clock signal. There is one clock pulse per bit of data.
Each data transfer is initiated with a Start condition and
terminated with a Stop condition. The number of the data bytes
transferred between Start and Stop conditions is determined by
the master device and is, theoretically unlimited , (although only
the last sixteen will be stored when doing a write operation)
When an overwrite does occur it will replace data in a first-in
first-lout (FIFO) fashion.
3.5
Acknowledge
Each receiving device, when addressed, is obliged to generate
an acknowledge after the reception of each byte. The master
device must generate an extra clock pulse which is associated
with this Acknowledge bit.
Note: The 24XX16 does not generate any Acknowledge bits if
an internal programming cycle is in progress.
The device that acknowledges, has to pull down the SDA line
during the acknowledge clock pulse in such a way that the SDA
line is stable low during the high period of the acknowledge
related clock pulse. Of course, setup and hold times must be
taken into account. During reads, a master must signal an end of
data to the slave by not generating an Acknowledge bit on the
last byte that has been clocked out of the slave. In this case, the
slave (24XX16) will leave the data line high to enable the master
to generate the Stop condition.
FIGURE 3-1:
DATA TRANSFER SEQUENCE ON THE SERIL BUS



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com