Back Button LM2596 Datasheet HTML 16Page - ARTSCHIP ELECTRONICS CO.,LMITED. LM2596 Datasheet HTML 17Page - ARTSCHIP ELECTRONICS CO.,LMITED. LM2596 Datasheet HTML 18Page - ARTSCHIP ELECTRONICS CO.,LMITED. LM2596 Datasheet HTML 19Page - ARTSCHIP ELECTRONICS CO.,LMITED. LM2596 Datasheet HTML 20Page - ARTSCHIP ELECTRONICS CO.,LMITED. LM2596 Datasheet HTML 21Page - ARTSCHIP ELECTRONICS CO.,LMITED. LM2596 Datasheet HTML 22Page - ARTSCHIP ELECTRONICS CO.,LMITED. LM2596 Datasheet HTML 23Page - ARTSCHIP ELECTRONICS CO.,LMITED. LM2596 Datasheet HTML 24Page - ARTSCHIP ELECTRONICS CO.,LMITED. Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 29 page
background image
LM2596
www.artschip.com
20
Application Information (Continued)
FIGURE 15 . Capacitor ESR Change vs Temperature
INDUCTOR SELECTION
All switching regulators have two basic modes of operation;
continuous and discontinuous. The difference between the two
types relates to the inductor current, whether it is flowing
continuously, or if it drops to zero for a period of time in the
normal switching cycle. Each mode has distinctively different
operating characteristics, which can affect the regulators
performance and requirements. Most switcher designs will
operate in the discontinuous mode when the load current is low.
The LM2596 (or any of the Simple Switcher family) can be used
for both continuous or discontinuous modes of operation.
In many cases the preferred mode of operation is the continuous
mode. It offers greater output power, lower peak switch, inductor
and diode currents, and can have lower output ripple voltage.
But it does require large inductor values to keep the inductor
current flowing continuously, especially at low output load
currents and / or high input voltages.
To simplify the inductor selection process, an inductor selection
guide (nomograph ) was designed ( see figure 4 through 8). This
guide assumes that the regulator is operating in the continuous
mode, and selects an inductor that will allow a peak-to-peak
inductor ripple current to be a certain percentage of the
maximum design load current. This peak-to-peak inductor ripple
current percentage is not fixed, but is allowed to change as
different design load currents are selected. (See Figure 16.)
FIGURE 16. (△I IND ) Peak-to-Peak Inductor Ripple Current
(as a Percentage of the load current)
Vs Load Current
By allowing the percentage of inductor ripple current to increase
for low load currents, the inductor value and size can be kept
relatively low.
When operating in the continuous mode, the inductor current
waveform ranges from a triangular to a sawtooth type of
waveform (depending on the input voltage), with the average
value of this current waveform equal to the DC output load
current.
Inductors are available in different styles such as pot core, toroid,
E-core, bobbin core, etc., as well as different core materials,
such as ferrites and powdered iron. The least expensive, the
bobbin, rod or stick core, consists of wire wound on a ferrite
bobbin, This type of construction makes for an inexpensive
inductor, but since the magnetic flux is not completely contained
within the core, it generates more Electro-Magnetic Interference
(EMI). This magnetic flux can induce voltages into nearby
printed circuit traces, thus causing problems with both the
switching regulator operation and nearby sensitive circuitry, and
can give incorrect scope readings because of induced voltages
in the scope probe. Also see section on Open Core Inductors.
When multiple switching regulators are located on the same PC
board, open core magnetics can cause interference between
two or more of the regulator circuits, especially at high currents.
A torroid or E-core inductor (closed magnetic structure) should
be used in these situations.
The inductors listed in the selection chart include ferrite E-core
construction for Schott, ferrite bobbin core for Renco and
Coilcraft, and powdered iron toroid for Pulse Engineering.
Exceeding an inductor’s maximum current rating may cause the
inductor to overheat because of the copper wire losses, or the
core may saturate. If the inductor begins to saturate, the
inductance decreases rapidly and the inductor begins to look
mainly resistive (the DC resistance of the winding). This can
cause the switch current to rise very rapidly and force the switch
into a cycle-by-cycle current limit, thus reducing the DC output
load current. This can also result in overheating of the inductor
and/or the LM2596. Different inductor types have different
saturation characteristics, and this should be kept in mind when
selecting an inductor.
The inductor manufacturer’s data sheets include current and
energy limits to avoid inductor saturation.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com