| Electronic Components Datasheet Search |
|
K30 Datasheet(PDF) 2 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
K30 Datasheet(HTML) 2 Page - Banner Engineering Corp. |
|
2 / 4 page ![]() Specifications Supply Voltage 12 V dc to 30 V dc Supply Current 55 mA max current (exclusive of load) Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Rating Maximum load: 150 mA ON-state saturation voltage: < 2 V dc at 10 mA; < 2.5 V dc at 150 mA OFF-state leakage current: < 10 µA at 30 V dc Output Response Time: 150 milliseconds On and Off Mounting M22 × 1.5 Threaded base, max torque 2.25 N·m (20 in·lbf) Connections Integral 4-pin M12/Euro-style QD, or 2 m (6.5 ft) PVC integral cable Power-Up Delay 300 milliseconds Construction Housing: polycarbonate Translucent dome: polycarbonate Mounting nut: PBT Indicator Characteristics Color Dominant Wavelength (nm) or Color Temperature (CCT) Lumen Output (Typical at 25 °C) Green 520 - 535 nm 4.4 Red 620 - 630 nm 1.7 Yellow 585 - 595 nm 4.4 Blue 465 - 475 nm 1.0 White 5665 - 9000K 5.0 Vibration and Mechanical Shock Vibration 10 Hz to 55 Hz 1.0 mm p-p amplitude per IEC 60068-2-6 Shock 30G 11 ms duration, half sine wave per IEC 60068-2-27 Environmental Rating Rated IEC IP67, and IP69K, per DIN 40050-9. Cabled models also meet IEC IP69K if the cable and cable entrance are protected from high-pressure spray. Indicator side of terminal models meet IEC IP67, and IEC IP69K when installed in an enclosure. Screw connection points meet IEC IP00. Meets UL type 4X and 13, when used in a suitable enclosure. Operating Conditions Temperature: –40 °C to +50 °C (–40 °F to +122 °F) Humidity: 90% at +50 °C maximum relative humidity (non-condensing) Storage –40 °C to +70 °C (–40 °F to +158 °F) Certifications Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. Quick-Disconnect Models Terminal Models 52.4 [2.06] 42 [1.65] M22 X 1.5 -6g Max. screw torque 0.11 Nm [1.0 lbf-in] EZ-LIGHT® Touch Gen 2 K30 Series Pick-to-Light 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 189827 Rev. E |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |