| Electronic Components Datasheet Search |
|
MAX9259 Datasheet(PDF) 39 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX9259 Datasheet(HTML) 39 Page - Maxim Integrated Products |
|
39 / 51 page ![]() 39 Maxim Integrated Gigabit Multimedia Serial Link with Spread Spectrum and Full-Duplex Control Channel MAX9259/MAX9260 Applications Information MAX9260 Error Checking The MAX9260 checks the serial link for errors and stores the number of detected decoding errors in the 8-bit register (DECERR, 0x0D). If a large number of decoding errors are detected within a short duration, the deserial- izer loses lock and stops the error counter. The deserial- izer then attempts to relock to the serial data. DECERR resets upon successful video link lock, successful readout of DECERR (through UART), or whenever auto- error reset is enabled. The MAX9260 does not check for decoding errors during the internal PRBS test and DECERR is reset to 0x00. ERR Output The MAX9260 has an open-drain ERR output. This output asserts low whenever the number of decoding errors exceed the error threshold (ERRTHR, 0x0C) dur- ing normal operation, or when at least one PRBS error is detected during PRBS test. ERR reasserts high when- ever DECERR (0x0D) resets, due to DECERR readout, video link lock, or autoerror reset. Autoerror Reset The default method to reset errors is to read the respec- tive error registers in the MAX9260 (0x0D, 0x0E). Auto- error reset clears the decoding-error counter (DECERR) and the ERR output ~1Fs after ERR goes low. Autoerror reset is disabled on power-up. Enable autoerror reset through AUTORST (0x06 D6). Autoerror reset does not run when the device is in PRBS test mode. Self PRBS Test The MAX9259/MAX9260 link includes a PRBS pat- tern generator and bit-error verification function. Set PRBSEN = 1 (0x04 D5) first in the MAX9259 and then the MAX9260 to start the PRBS test. Set PRBSEN = 0 (0x04 D5) first in the MAX9260 and then the MAX9259 to exit the PRBS self test. The MAX9260 uses an 8-bit register (0x0E) to count the number of detected errors. The control link also controls the start and stop of the error counting. During PRBS mode, the device does not count decoding errors and the ERR output reflects PRBS errors only. Autoerror reset does not run when the device is in PRBS mode. Microcontrollers on Both Sides of the GMSL Link (Dual µC Control) Usually the FC is either on the serializer (MAX9259) side for video-display applications, or on the deserial- izer (MAX9260) side for image-sensing applications. For the former case, both the CDS pins of the MAX9259/ MAX9260 are set to low, and for the later case, the CDS pins are set to high. However, if the CDS pin of the MAX9259 is low and the CDS pin of the MAX9260 is high, then the MAX9259/MAX9260 can both connect to FCs simultaneously. In such a case, the FCs on either side can communicate with the MAX9259/MAX9260 UART protocol. Contentions of the control link may happen if the FCs on both sides are using the link at the same time. The MAX9259/MAX9260 do not provide the solution for contention avoidance. The serializer/deserealizer do not send an acknowledge frame when communication fails due to contention. Users can always implement a higher- layer protocol to avoid the contention. In addition, if UART communication across the serial link is not required, the F Cs can disable the forward and reverse control channel through the FWDCCEN and REVCCEN bits (0x04 D[1:0]) in the MAX9259/MAX9260. UART communication across the serial link is stopped and contention between FCs no longer occurs. During the dual FC operation, if one of the CDS pins on either side changes state, the link resumes the corresponding state described in the Link Startup Procedure section. As an example of dual FC use in an image-sensing link, the MAX9259 may be in sleep mode and waiting to be waked up by the MAX9260. After wake-up, the serializer- side FC sets the MAX9259 CDS pin low and assumes master control of the MAX9259 registers. Jitter-Filtering PLL In some applications, the parallel bus input clock to the MAX9259 (PCLKIN) includes noise, which reduces link reliability. The MAX9259 has a narrow-band jitter-filtering PLL to attenuate frequency components outside the PLL’s bandwidth (< 100kHz typ). Enable the jitter-filtering PLL by setting DISFPLL = 0 (0x05 D6). Changing the Data Frequency Both the video data rate (fPCLK_) and the control data rate (fUART) can be changed on-the-fly to support applications with multiple clock speeds. Slow speed/ performance modes allow significant power savings when a system’s full capabilities are not required. Enable the MAX9259/MAX9260 link after PCLK_ stabilizes. Stop PCLKIN for 5µs and restart the serial link or toggle SEREN after each change in the parallel clock frequency to recalibrate any automatic settings if a clean frequency change cannot be guaranteed. The reverse control channel remains unavailable for 350Fs after serial link start or stop. Limit on-the-fly changes in fUART to fac- tors of less than 3.5 at a time to ensure that the device |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |