CJ1W-SCU Datasheet(PDF) 4 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
CJ1W-SCU Datasheet(HTML) 4 Page - Omron Electronics LLC |
|
4 / 16 page ![]() 4 CJ1W-SCU Protocol Specifications Host Link Specifications *1. Confirm the baud rates and communications distance supported by connected devices. *2. The CJ1W-SCU @2 is required for communications at 230,400 bps. *3. The maximum cable length for RS-232C is 15 m. The RS-232C standard, however, does not cover baud rates above 19.2 Kbps. Refer to the manual for the device being connected to confirm support. *4. The specified frame format must be prepared on the host computer and then sent. *5. The host computer must interpret the commands and return a response in the correct format. Connection between the host computer and Controller must be 1:1. Protocol Macro Function Specifications Item Description Communications mode Half-duplex (Full-duplex for slave-initiated communications) Synchronous mode Start-stop synchronization (asynchronous mode) Baud rate *1 RS-232C port and RS-422A/485 ports: 1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200/230,400 bps *2 Default setting: 9,600 bps Communications distance *1 RS-232C port : 15 m max. *3 RS-422A/485 Port : • CJ1W-SCU @1-V1 500 m max. (total cable length: 500 m max., T-branch branch lines: 10 m max.) • CJ1W-SCU @2 1,200 m max. (total cable length: 1,200 m max., Multidrop connections are possible. However, maximum cable length is 500 m if the NT-AL001 is used for RS-422A-485 connections.) Connection configuration RS-232C port : 1:1 (1:N (N = 32 Units max.) is possible using an Converting Link Adapters.) RS-422A/485 port : 1:N (N = 32 Units max.) Number of connected Units 32 Units max. (unit numbers 0 to 31; unit number 0 is set for 1:1 connection) Frame structure C-mode commands Header: @, address: (host link unit number) 0 to 31 (BCD), data: header code + text, error check code: FCS, terminator: * +CR FINS commands Header: @, address: (host link unit number) 0 to 31 (BCD), data: header code (always “FA”) + FINS header + FINS command + text, error check code: FCS, terminator: * +CR Error check codes Vertical parity: Even, odd. or none FCS (horizontal parity converted to ASCII) Command flow and support Command flow Commands Contents Host computer to Controller C-mode commands 1:1 or 1:N communications with directly connected Controller *4 FINS commands (in Host Link protocol) 1:1 or 1:N communications with directly connected Controller. Controller to host computer FINS commands (in Host Link protocol) Communications using SEND(090), RECV(098), and CMND(490) from CPU Unit. *5 Item Description Number of protocols 20 max. Can be created and registered with the Protocol Support Tool (CX-Protocol). Number of sequences 1,000 max. Per protocol Number of sequences 60 max. Number of messages 300 max. Number of reception matrixes 100 max. Sequence execution condition Using the CPU Unit’s PMCR (260) instruction (specifying the sequence number) Communications mode Half-duplex or full-duplex Synchronous mode Start-stop synchronization (asynchronous mode) Baud rate *1 RS-232C port and RS-422A/485 ports: 1,200/2,400/4,800/9,600/19,200/38,400/57,600/115,200/230,400 bps Default setting: 9,600 bps *2 Communications distance *1 RS-232C port : 15 m max. RS-422A/485 port : • CJ1W-SCU @1-V1 500 m max. (total cable length: 500 m max., T-branch branch lines: 10 m max.) • CJ1W-SCU @2 1,200 m max. (total cable length: 1,200 m max., Multidrop connections are possible. However, max- imum cable length is 500 m if the NT-AL001 is used for RS-422A-485 connections.) Connection configuration RS-232C port : 1:1 (1:N (N = 32 Units max.) is possible using a Converting Link Adapter.) RS-422A/485 port : 1:N (N = 32 Units max.) Number of connected Units 32 Units max. (unit numbers 0 to 31; unit number 0 is set for 1:1 connection) Maximum number of data exchange words between Controller and protocol macro function Operand setting 250 words Including the word that specifies the number of words (1 word) Link word setting 500 words O1, O2, I1, and I2: 500 words total Direct setting 500 words Maximum number of words per data attribute |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |