Back Button TPS727 Datasheet HTML 10Page - Texas Instruments TPS727 Datasheet HTML 11Page - Texas Instruments TPS727 Datasheet HTML 12Page - Texas Instruments TPS727 Datasheet HTML 13Page - Texas Instruments TPS727 Datasheet HTML 14Page - Texas Instruments TPS727 Datasheet HTML 15Page - Texas Instruments TPS727 Datasheet HTML 16Page - Texas Instruments TPS727 Datasheet HTML 17Page - Texas Instruments TPS727 Datasheet HTML 18Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 36 page
background image
I
(mA)=C
( F)
0.07(V/ s)+I
(mA)
m
m
LOAD
SOFTSTART
OUT
´
TPS727
SBVS128F – JUNE 2009 – REVISED DECEMBER 2015
www.ti.com
Typical Application (continued)
8.2.2 Detailed Design Procedure
Select the desired device based on the output voltage.
Provide an input supply with adequate headroom to include dropout and output current to account for the GND
pin current and to power the load.
Select adequate input and output capacitors.
The startup current is given by Equation 2:
(2)
Equation 2 shows that soft-start current is directly proportional to COUT.
The output voltage ramp rate is independent of COUT and load current and has a typical value of 0.07 V/μs.
The TPS727 automatically adjusts the soft-start current to supply both the load current and the COUT charge
current. For example, if ILOAD = 0 mA upon enabling the LDO, ISOFT START = 1 μF × 0.07 V/μs + 0 mA = 70 mA,
the current that charges the output capacitor.
If ILOAD = 200 mA, ISOFT START = 1 μF × 0.07 V/μs + 200 mA = 270 mA, the current required for charging output
capacitor and supplying the load current.
If the output capacitor and load are increased such that the soft-start current exceeds the output current limit, the
current is clamped at the typical current limit of 400 mA. For example, if COUT = 10 μF and IOUT = 200 mA, 10 μF
× 0.07 V/
μs + 200 mA = 900 mA is not supplied. Instead, the current is clamped at 400 mA.
14
Submit Documentation Feedback
Copyright © 2009–2015, Texas Instruments Incorporated



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com