16 / 49 page ![]() OUT ON(min) SW IN V t F V ! ˜ (6) where • tON(min) is 49 ns (typical) • FSW is the switching frequency If the desired voltage conversion ratio does not meet the above condition, the LM25149 transitions from fixed switching frequency operation to a pulse-skipping mode to maintain output voltage regulation. For example, if the desired output voltage is 5 V with an input voltage of 24 V and switching frequency of 2.1 MHz, the voltage conversion ratio test in Equation 7 is satisfied. ! ˜ ! 5 V 59 ns 2.1 MHz 24 V 0.208 0.124 (7) For wide-VIN applications and low output voltages, an alternative is to reduce the LM25149 switching frequency to meet the requirement of Equation 6. 8.3.11 Error Amplifier and PWM Comparator (FB, EXTCOMP) The LM25149 has a high-gain transconductance amplifier that generates an error current proportional to the difference between the feedback voltage and an internal precision reference (0.8 V). The control loop compensation is configured two ways. The first is using the internal compensation amplifier, which has a transconductance of 30 µS. Internal compensation is configured by connecting the EXTCOMP pin through a 100-kΩ resistance to VDDA. If a 100-kΩ resistor is not detected, the LM25149 defaults to the external loop compensation network. The transconductance of the amplifier for external compensation is 1200 µS. This is latched and cannot be re-configured on the fly. Use an external compensation network if higher performance is required to meet a stringent transient response. To re-configure the compensation (internal or external), remove power and allow VCC to drop below its VCCUVLO threshold, which is 3.3 V typical. A type-II compensation network is generally recommended for peak current-mode control. 8.3.12 Slope Compensation The LM25149 provides internal slope compensation for stable operation with peak current-mode control and a duty cycle greater than 50%. Calculate the buck inductance to provide a slope compensation contribution equal to one times the inductor downslope using Equation 8. OUT S O-IDEAL SW V (V) R (m ) L ( + 24 F (MHz) ˜ : ˜ (8) • A lower inductance value generally increases the peak-to-peak inductor current, which minimizes size and cost, and improves transient response at the cost of reduced light-load efficiency due to higher cores losses and peak currents. • A higher inductance value generally decreases the peak-to-peak inductor current, reducing switch peak and RMS currents at the cost of requiring larger output capacitors to meet load-transient specifications. 8.3.13 Inductor Current Sense (ISNS+, VOUT) There are two methods to sense the inductor current of the buck power stage. The first uses a current sense resistor (also known as a shunt) in series with the inductor, and the second avails of the DC resistance of the inductor (DCR current sensing). LM25149 SNVSBV5 – DECEMBER 2020 www.ti.com 16 Submit Document Feedback Copyright © 2020 Texas Instruments Incorporated Product Folder Links: LM25149 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |