Back Button ISOW7741FDFM Datasheet HTML 21Page - Texas Instruments ISOW7741FDFM Datasheet HTML 22Page - Texas Instruments ISOW7741FDFM Datasheet HTML 23Page - Texas Instruments ISOW7741FDFM Datasheet HTML 24Page - Texas Instruments ISOW7741FDFM Datasheet HTML 25Page - Texas Instruments ISOW7741FDFM Datasheet HTML 26Page - Texas Instruments ISOW7741FDFM Datasheet HTML 27Page - Texas Instruments ISOW7741FDFM Datasheet HTML 28Page - Texas Instruments ISOW7741FDFM Datasheet HTML 29Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 41 page
background image
9.3.2 Power-Up and Power-Down Behavior
The ISOW7741 device has built-in UVLO on the VIO, VDD, and VISOIN supplies with positive-going and negative-
going thresholds and hysteresis. Both the power converter supply (VDD) and logic supply (VIO) need to be
present for the device to work. If either of them is below its UVLO, both the signal path and the power converter
are disabled.
When the VDD voltage crosses the positive-going UVLO threshold during power-up, the DC-DC converter
initializes and the power converter duty cycle is increased in a controlled manner. This soft-start scheme limits
primary peak currents drawn from the VDD supply and charges the VISOOUT output in a controlled manner,
avoiding overshoots. Outputs of the isolated data channels are in an indeterminate state until the VIO or VDD
voltage crosses the positive-going UVLO threshold. When the UVLO positive-going threshold is crossed on the
secondary side VISOOUT pin, the feedback data channel starts providing feedback to the primary controller. The
regulation loop takes over and the isolated data channels go to the normal state defined by the respective input
channels or their default states. Design should consider a sufficient time margin (typically 10 ms with 10-µF load
capacitance) to allow this power up sequence before valid data channels are accounted for system functionality.
When either VIO or VDD power is lost, the primary side DC-DC controller turns off when the UVLO lower
threshold is reached. The VISOOUT capacitor then discharges depending on the external load. The isolated data
outputs on the VISOIN side are returned to the default state for the brief time that the VISOIN voltage takes to
discharge to zero.
9.3.3 Protection Features
The ISOW7741 devicehas multiple protection features to create a robust system level solution.
• The first feature is an Enable DC-DC /fault protection feature. This pin can be used as either an input pin to
enable or disable the integrated DC-DC power converter or as an output pin which works as an alert signal if
the power converter is not operating properly. In the /fault use case, a fault is reported if VDD > 7 V, VDD < 2.5
V, or if the junction temperature >170°C. When a fault is detected, this pin will go low, disabling the DC-DC
converter to prevent any damage.
MCU
OUTPUT
MCU INPUT
Powers down digital isolator
and DCDC converter.
IQ < 1mA typical
Fault reported if
VDD < 2.5 V
VDD > 7 V
Junction Temp > 170° C
EN_DCDC
• 5 k
Figure 9-4. EN_DCDC Fault Pin Diagram
• Over-voltage lock out on VDD will occur when a voltage higher than 7 V is seen. The device will go into a low
power state and the EN_DCDC pin will go low. It is highly recommended that the VDD abs max condition of
6V is not violated.
• An over-voltage clamp feature is present on VISOOUT which will clamp the voltage at 6V if there is an increase
in voltage seen.
• The device is protected against output overload and short circuit. Output voltage starts dropping when the
power converter is not able to deliver the current demanded during overload conditions. For a VISO short-
circuit to ground, the duty cycle of the converter is limited to help protect against any damage.
• The device is protected against output overload and short circuit. Output voltage starts dropping when the
power converter is not able to deliver the current demanded during overload conditions. For a VISO short-
circuit to ground, the duty cycle of the converter is limited to help protect against any damage.
• The device is protected against output overload and short circuit. Output voltage starts dropping when the
power converter is not able to deliver the current demanded during overload conditions. For a VISO short-
circuit to ground, the duty cycle of the converter is limited to help protect against any damage.
www.ti.com
ISOW7741
SLLSFK1 – DECEMBER 2020
Copyright © 2020 Texas Instruments Incorporated
Submit Document Feedback
25
Product Folder Links: ISOW7741



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com