| Electronic Components Datasheet Search |
|
ADS131M04IPWT Datasheet(PDF) 83 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
ADS131M04IPWT Datasheet(HTML) 83 Page - Texas Instruments |
|
83 / 99 page ![]() 9.2.1 Design Requirements Table 9-2. Key System Specifications FEATURES DESCRIPTION Number of phases 1 phase (split-phase with two voltages measured) E-meter accuracy class Class 0.1 Current sensor Current transformer Current range 0.05 A to 100 A System nominal frequency 50 Hz or 60 Hz Measured parameters • Active, reactive, apparent power, and energy • Root mean square (RMS) current and voltage • Power factor • Line frequency 9.2.2 Detailed Design Procedure A current sensor connects to the current channels and a simple voltage divider is used for the corresponding voltage measurement. The CT has an associated burden resistor that must be connected at all times to protect the measuring device. The selection of the CT and the burden resistor is made based on the manufacturer and current range required for energy measurements. The voltage divider resistors for the voltage channel are selected to ensure the mains voltage is divided down to adhere to the normal input voltage ranges of the ADS131M04. In this design, the ADS131M04 interacts with a microcontroller (MCU) in the following manner: • The CLKIN clock used by the ADS131M04 device is provided by the MCU • When new ADC samples are ready, the ADS131M04 device asserts its DRDY pin, which alerts the MCU that new samples are available • After being alerted of new samples, the MCU uses one of its SPI interfaces to retrieve the voltage and current samples from the ADS131M04 9.2.2.1 Voltage Measurement Front-End The nominal voltage from the mains is from 100 V – 240 V so this voltage must be scaled down to be sensed by an ADC. Figure 9-9 shows the analog front-end used for this voltage scaling. Live Neutral R FILT C FILT R FILT R LO R HI R HI R HI R V AINxP AINxN Figure 9-9. Voltage Measurement Front-End The analog front-end for voltage consists of a spike protection varistor (RV), a voltage divider network (RHI and RLO), and an RC low-pass filter (RFILT and CFILT). Equation 11 shows how to calculate the range of differential voltages fed to the voltage ADC channel for a given mains voltage and the selected voltage divider resistor values. LO ADC RMS HI LO R V V 2 3R R r u u (11) RHI is 300 kΩ and RLO is 750 Ω in this design. For a mains voltage of 120 V (as measured between the line and neutral), the input signal to the voltage ADC has a voltage swing of ±128 mV (91 mVRMS) based on Equation 11 and the selected resistor values. This voltage is well within the ±1.2-V input voltage range that can be sensed by the ADS131M04 for the selected PGA gain value of 1 that is used for the voltage channels. www.ti.com ADS131M04 SBAS890C – MARCH 2019 – REVISED JANUARY 2021 Copyright © 2021 Texas Instruments Incorporated Submit Document Feedback 83 Product Folder Links: ADS131M04 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |