| Electronic Components Datasheet Search |
|
DAC01 Datasheet(PDF) 2 Page - Carlo Gavazzi Holding AG |
|
|
|||||||||||||||||||||||||||||
DAC01 Datasheet(HTML) 2 Page - Carlo Gavazzi Holding AG |
|
2 / 3 page ![]() 2 Specifications are subject to change without notice (20.06.07) DAC01, PAC01 Supply Specifications General Specifications Power supply Overvoltage cat. III Rated operational voltage (IEC 60664, IEC 60038) through terminals: A1 and A2 (DAC01) 2, 10 (PAC01) M24 24 to 240 VAC/DC +10% -15%, 45 to 65 Hz M40: 380 to 415 VAC +10% -15%, 45 to 65 Hz Voltage interruption ≤ 10 ms Rated operational power M24 AC Supply: 4 VA DC Supply: 1.5 W M40 AC Supply: 13 VA @ 400 VAC, 50 Hz Power ON delay ≤ 100 ms Power OFF delay ≤ 100 ms Indication for Power supply ON LED, green Output relays ON LED, yellow (flashing when timing) Environment (EN 60529) Degree of protection IP 20 Pollution degree 3 (DAC01) ,2 (PAC01) (IEC 60664) Operating temperature -20 to 60 °C, R.H. < 95% Storage temperature -30 to 80 °C, R.H. < 95% Housing Dimensions DAC01 22.5 x 80 x 99.5 mm PAC01 36 x 80 x 94 mm Weight Approx 110 g Screw terminals DAC01 Tightening torque Max 0.5 Nm according to IEC EN 60947 Approvals UL, CSA CE Marking Yes EMC Electromagnetic Compatibility Immunity According to EN 61000-6-2 Emission According to EN 61000-6-3 Timer Specifications According to EN 61812-1 Mode of Operation The output relay is normally in the neutral centre position. When the power supply is applied, the relay switches to star position (pin 16 or 4) and the star period starts. At the end of the set time period, the relay returns to the neutral centre position and the set delay between star and delta position starts. At the end of the star to delta delay (adjustable from 50 to 130 ms), the relay switches in delta position (pin 18 or 3) and does not release until the power sup- ply is interrupted for at least 200 ms. If the power supply is inter- rupted for more than 200 ms before the star time period has expired, the relay does not operate and the time cir- cuit is set to zero. The relay is ready for a new time period. Time Setting Upper knob: Setting of star time range Centre knob: Star time setting on relative scale: 1 to 10 with respect to the chosen range. Lower knob: Star to delta time setting (50 to 130 ms) Operation Diagram PowerSupply RelayON(15-16)Y RelayON(15-18)D T Y T Y T Y-D T Y-D ³ 200ms ³ 200ms £ 40 ms ≤ 10 ms ON OFF ON OFF |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |