5 / 5 page ![]() IL33197 5 The following table summarizes all T1 debounce timings: Condition Debounce Time INT Active 4 x tb1 to 2 x 4 x tb1 INT Inactive 4 x tb1 to 2 x 4 x tb1 W/W Active When INT Inactive 4 x tb1 to 2 x 4 x tb1 W/W Active When INT Active During T3 4 x tb1 to 2 x 4 x tb1 W/W Active When INT Active During T4 4 x tb2 to 2 x 4 x tb2 Two IL33197A Devices Using One Decoupling Resistor and Capacitor Two devices may be connected to the power source using a common R1 resistor for protection against overvoltages. If this is done it should be noted that the current flowing through R1 is increased and hence the voltage drop across R1 is increased. Overvoltage Protection In reference to the Block Diagram and Typical Application, all of the foregoing operational cases require: R1 ≥ 100 Ω, C1 ≥ 47 µF R3 ≥ 1.0 kΩ, R4 ≥ 4.7 kΩ, R5 ≥ 4.7 kΩ The circuit will not operate during the transient conditions. By using the above component values, the circuit will be able to sustain the following overvoltages on Vbb without permanent damage: 1. +28 V for 5 minutes 2. –15 V for 5 minutes 3. –16 V cycled off for 1.0 minute 4. +80 V pulse decaying exponentially to 8.0 V in 400 ms repeated 3 times at 1.0 minute intervals. 5. ±300 V pulse decaying exponentially to 30 V in 300 ms with a maximum energy of 1.0 Joule. 6. ±100 V pulse decaying exponentially to 10 V in 2 ms. Recommended External Component Values Below are the recommended component values to ensure the device will operate properly, and that all specified parameters will stay within their tolerances. R1 should be greater than 100 Ω; recommended value of 220 Ω. R1 can be up to 500 Ω, but in this case the tb2v parameter could be out of it’s specified value (see Electrical Characteristics and Note 1). Also, the minimum operating voltage range should be greater than 8.0 V. The following values should be adhered to: 10 k Ω ≤ R2 ≤ 68 kΩ; 1.5 kΩ ≤ R3 ≤ 47 kΩ; R4 ≥ 4.7 kΩ; R5 ≥ 4.7 kΩ; C1 ≥ 47 uF; 47 nF ≥ C2 ≥ 470 nF Application Information The following is an example of timing calculations using the following external components values: R2 = 22 k Ω, R3 = 2.2 kΩ, C2 = 100 nF (Referring to Block Diagram and Typical Application). Oscillator Time Base Calculation: tb1 duration = tb1 x 4 x R2 x C2 = 1 x 4 x 27e3 x 100e–9 = 10.8 ms; tb2 duration_g (INT to Gnd) = tb2g x R3 x C2 = 15.5 x 2.2e3 x 100e–9 = 3.41 ms tb2 duration_v (INT to Vbb) = tb2v x R3 x C2 = 12.1 x 2.2e3 x 100e–9 = 2.66 ms Intermittent timing calculation: T3 = 16 x 4 x tb1 duration = 16 x 4 x 10.8 ms = 691 ms T4 = 144 x 4 x tb2 duration_g = 144 x 4 x 3.41 ms = 1.96 s (INT connected to Gnd) T4 = 144 x 4 x tb2 duration_v = 144 x 4 x 2.66 ms = 1.53 s (INT connected to Vbb) Wash wipe timing calculation: T2 = 96 x 4 x tb1 = 96 x 4 x 10.8 ms = 4.15 s T1 Debounce Time Calculation (see T1 Debounce Timing) When oscillator is oscillating at tb1: T1 minimum = 4 x tb1 = 4 x 10.8 ms = 43.2 ms T1 maximum = 2 x 4 x tb1 = 2 x 4 x 10.8 ms = 86.4 ms When oscillator is oscillating at tb2: T1 minimum (INT connected to Gnd, tb2g) = 4 x tb2 = 4 x 3.41 ms = 13.6 ms T1 maximum (INT connected to Gnd, tb2g) = 2 x 4 x tb2 = 2 x 4 x 3.41 ms = 27.3 ms |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |