MODEL: 6PA
6PA SPECIFICATIONS
ES-4233 Rev.9 Page 1/2
http://www.m-system.co.jp/
Field-mounted Two-wire Signal Conditioners 6-UNIT
FREQUENCY TRANSMITTER
(field-selectable freq. range)
Functions & Features
• Converting the output from a pulse-type transducer into a
standard 4 – 20 mA DC signal
• Field selectable frequency range
• Rugged enclosure
Typical Applications
• Positive displacement flowmeters, turbine flowmeters and
vortex flowmeters
• Proximity switches
• Oval flowmeters
76
(2.99) DIA.
60.9 (2.40)
52.5
(2.07)
mm (inch)
MODEL: 6PA-2
ORDERING INFORMATION
• Code number: 6PA-2
• Frequency range (e.g. 0 – 500 Hz)
User’s frequency range specified when ordering determines
the field adjustable range of the 6PA. Refer to the table
below and check the range before ordering.
ORDER SPECIFIED FREQ: ADJUSTABLE RANGE
36 Hz – 100 Hz: 36 Hz – 120 Hz
100 Hz – 240 Hz: 90 Hz – 300 Hz
240 Hz – 480 Hz: 180 Hz – 600 Hz
480 Hz – 1.0 kHz: 360 Hz – 1.2 kHz
1.0 kHz – 2.4 kHz: 0.9 kHz – 3.0 kHz
2.4 kHz – 4.8 kHz: 1.8 kHz – 6.0 kHz
4.8 kHz – 12 kHz: 3.6 kHz – 12 kHz
• Mounting adapter (e.g. surface mounting adapter plate,
model: A-01)
Note: When a mounting adapter is required, specify
mounting adapter. Not included without specifying.
INPUT
2: Voltage pulse
RELATED PRODUCTS
• Outdoor enclosure (model: 6BX-E)
PACKAGE INCLUDES...
• Mounting adapter
surface mounting adapter plate (model: A-01)
Spring clip (model: A-02)
DIN rail mounting plate (model: A-31)
Note: When a mounting adapter is required, specify
mounting adapter. Not included without specifying.
When using in combination with outdoor enclosure (model:
6BX-E), use a spring clip (model: A-02).
GENERAL SPECIFICATIONS
Connection: M3 screw terminals (torque 0.6 N·m)
Screw terminal: Nickel-plated steel
Housing material: Diecast aluminum
Zero adjustment: -5 to +5 % (behind the access cover)
Span adjustment: 95 to 105 % (behind the access cover)
Rotary switch: For input calibration
(Refer to the instruction manual)
INPUT SPECIFICATIONS
■ Voltage Pulse:
Frequency range: 0 – 36 Hz through 12 kHz
Input amplitude:
100 mVp-p – 50 Vp-p (≤ 1.2 kHz range)
200 mVp-p – 50 Vp-p (≥ 0.9 kHz range)
Pulse width requirement: Duty ratio 20 – 80 %
Input impedance: 100 kΩ
OUTPUT SPECIFICATIONS
Output: 4 – 20 mA DC
Load resistance vs. supply voltage: Load Resistance (Ω) =
(Supply Voltage (V) – 13 (V)) ÷ 0.02 (A)
(including leadwire resistance)
10
15
20
25
28
13
0
150
300
450
600
750
SUPPLY VOLTAGE [V]
(550Ω maximum at 24V DC)


Similar Part No. - 6PA

ManufacturerPart #DatasheetDescription
logo
Honeywell Solid State E...
6PA130-EX HONEYWELL-6PA130-EX Datasheet
942Kb / 7P
Interactive Catalog Replaces Catalog Pages
6PA131-EX HONEYWELL-6PA131-EX Datasheet
942Kb / 7P
Interactive Catalog Replaces Catalog Pages
6PA134-OP HONEYWELL-6PA134-OP Datasheet
942Kb / 7P
Interactive Catalog Replaces Catalog Pages
6PA136-EX HONEYWELL-6PA136-EX Datasheet
942Kb / 7P
Interactive Catalog Replaces Catalog Pages
logo
Texas Instruments
6PA24IPFBRG4 TI2-6PA24IPFBRG4 Datasheet
1Mb / 59P
Low-Power, Highly-Integrated, Programmable 16-Bit, 26-KSPS, Dual-Channel CODEC
REVISED APRIL 2005
More results

Similar Description - 6PA

ManufacturerPart #DatasheetDescription
logo
M-System Co.,Ltd.
6AC MSYSTEM-6AC Datasheet
101Kb / 3P
Field-mounted Two-wire Signal Conditioners 6-UNIT
6DV MSYSTEM-6DV Datasheet
153Kb / 4P
Field-mounted Two-wire Signal Conditioners 6-UNIT
6DVIB MSYSTEM-6DVIB Datasheet
200Kb / 8P
Field-mounted Two-wire Signal Conditioners 6-UNIT
6FN MSYSTEM-6FN Datasheet
94Kb / 2P
Field-mounted Two-wire Signal Conditioners 6-UNIT
6LC MSYSTEM-6LC Datasheet
99Kb / 2P
Field-mounted Two-wire Signal Conditioners 6-UNIT
6PT MSYSTEM-6PT Datasheet
101Kb / 2P
Field-mounted Two-wire Signal Conditioners 6-UNIT
6SN MSYSTEM-6SN Datasheet
96Kb / 3P
Field-mounted Two-wire Signal Conditioners 6-UNIT
6TS MSYSTEM-6TS Datasheet
110Kb / 3P
Field-mounted Two-wire Signal Conditioners 6-UNIT
6VS MSYSTEM-6VS Datasheet
101Kb / 2P
Field-mounted Two-wire Signal Conditioners 6-UNIT
A01 MSYSTEM-A01 Datasheet
87Kb / 2P
Field-mounted Two-wire Signal Conditioners 6-UNIT
More results


Html Pages

1 2


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com