Back Button ADPD4001 Datasheet HTML 24Page - Analog Devices ADPD4001 Datasheet HTML 25Page - Analog Devices ADPD4001 Datasheet HTML 26Page - Analog Devices ADPD4001 Datasheet HTML 27Page - Analog Devices ADPD4001 Datasheet HTML 28Page - Analog Devices ADPD4001 Datasheet HTML 29Page - Analog Devices ADPD4001 Datasheet HTML 30Page - Analog Devices ADPD4001 Datasheet HTML 31Page - Analog Devices ADPD4001 Datasheet HTML 32Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 28 / 82 page
background image
ADPD4000/ADPD4001
Data Sheet
Rev. A | Page 28 of 82
Table 18. Register Settings for Integrator Chop Mode
Group
Time Slot A
Register Address1
Bit Field Name
Description
Integrator
Chop Mode
0x010D
SUBTRACT_x
Four-pulse subtract pattern. Set to 1 to negate the math operation in the
matching position in a group of four pulses. The LSB maps to the first pulse.
0x010D
REVERSE_INTEG_x
Four-pulse integration reverse pattern. Set to 1 to reverse the integrator
positive and negative pulse order in the matching position in a group of four
pulses. The LSB maps to the first pulse.
1
This is the Time Slot A register address. Add 0x020 for the identical register address for each subsequent time slot. For example, Register 0x010D is the location for
SUBTRACT_A. For Time Slot B, this register is at Address 0x012D, For Time Slot C, this register is at Address 0x014D. For Time Slot D, this register is at Address 0x016D,
and so on.
Connection Modulation
The ADPD4000/ADPD4001 use three different types of modula-
tion connections to a sensor, controlled by the MOD_TYPE_x
bit field. Table 19 shows the different functions controlled by
this register. The default mode of operation is MOD_TYPE_x =
0, which is the mode where there is no modulation of the input
connection, and is the mode used as described in the Using
LED as Stimulus section.
Table 19. Modulation Connections Based on MOD_TYPE_x
MOD_TYPE_x
Connect function
0
TIA is continuously connected to INx after the
precondition period. There is no modulation of
the input connection.
1
Float mode operation. The TIA is connected to
INx only during the modulation pulse and
disconnected (floated) between pulses.
2
Nonfloat mode connection modulation. The
TIA is connected to INx during the modulation
pulse and connected to the precondition value
between pulses.
Float Mode Operation
The ADPD4000/ADPD4001 have a unique operating mode, float
mode, that allows high SNR at low power in low light situations.
In float mode, the photodiode is first preconditioned to a known
state and then the photodiode anode is disconnected from the
receive path of the device for a preset amount of float time.
During the float time, light falls on the photodiode, either from
ambient light, pulsed LED light, or a combination of the two
depending on the operating mode. Charge from the sensor is
stored directly on the capacitance of the sensor, CPD. At the end
of the float time, the photodiode is switched into the receive
path of the ADPD4000/ADPD4001 and an inrush of the
accumulated charge occurs, which is then integrated, allowing
the maximum amount of charge to be processed per pulse with
the minimum amount of noise added by the signal path. The
charge is integrated externally on the capacitance of the
photodiode for as long as it takes to acquire maximum charge,
independent of the amplifiers of the signal path, effectively
integrating charge noise free. Float mode allows the user the
flexibility to increase the amount of charge per measurement by
either increasing the LED drive current or by increasing the
float time.
In float mode, the signal path bypasses the BPF and uses only
the TIA and integrator. The BPF is bypassed because the shape
of the signal produced when transferring the charge from the
photodiode by modulating the connection to the TIA can differ
across devices and conditions. A filtered signal from the BPF is
not able to be reliably aligned with the integration sequence.
Therefore, the BPF cannot be used. In float mode, the entire
charge transfer is integrated in the negative cycle of the
integrator and the positive cycle cancels any offsets.
Float LED Mode for Synchronous LED Measurements
Float LED mode is desirable in low signal conditions where the
CTR is <10 nA/mA. In addition, float mode is an ideal option
when limiting the LED drive current of the green LEDs in a
heart rate measurement to keep the forward voltage drop of the
green LED to a level that allows the elimination of a boost
converter for the LED supply. For example, the LED current can
be limited to 10 mA to ensure that the LED voltage drop is ~3 V
so that it can operate directly from the battery without the need
of a boost converter. Float mode accumulates the received
charge during longer LED pulses without adding noise from the
signal path, effectively yielding the highest SNR per photon
attainable.
In float LED mode, multiple pulses are used to cancel electrical
offsets, drifts, and ambient light. To achieve this ambient light
rejection, an even number of equal length pulses are used. For
every pair of pulses, the LED flashes in one of the pulses and
does not flash in the other. The return from the combination of
the LED, ambient light, and offset is present in one of the pulses.
In the other, only the ambient light and offset is present. A
subtraction of the two pulses is made that eliminates ambient
light as well as any offset and drift. It is recommended to use
groups of four pulses for measurement where the LED is flashed
on Pulse 2 and Pulse 3. The accumulator adds Pulse 2 and Pulse 3
and then subtracts Pulse 1 and Pulse 4. To gain additional SNR,
use multiple groups of four pulses.
For each group of four pulses, the settings of LED_DISABLE_x
determine if the LED flashes in a specific pulse position. Which
pulse positions are added or subtracted is configured in the
SUBTRACT_x bit field. These sequences are repeated in groups
of four pulses. The value written to the FIFO or data registers is
dependent on the total number of pulses per sample period.
With NUM_INT_x set to 1, NUM_REPEAT_x determines the
total number of pulses. For example, if the device is set up for



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com