| Electronic Components Datasheet Search |
|
R10M-CT4E-R Datasheet(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R10M-CT4E-R Datasheet(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 7 page ![]() MODEL: R10M-CT4E R10M-CT4E SPECIFICATIONS ES-6247 Rev.0 Page 2/7 https://www.m-system.co.jp/ MODBUS COMMUNICATION RS-485 Standard: Conforms to TIA/EIA-485-A Protocol: Modbus-RTU Transmission distance: 500 meters max. Transmission media: Shielded twisted-pair cable (CPEV-S 0.9 dia.) Status indicator LED: RD, SD Transmission setting: PC configurator software INPUT SPECIFICATIONS Input setting: PC configurator software Clamp-on current sensor (CT1, CT2) Input (sensor & range) CLSE-R5: 0 – 5 A CLSE-05: 0 – 50 A CLSE-10: 0 – 100 A CLSE-20: 0 – 200 A CLSE-40: 0 – 400 A CLSE-60: 0 – 600 A Frequency: 50 / 60 Hz (45 - 65 Hz) Operational range: 0 – 105 % of rating Overload capacity CLSE-R5: 10 A continuous CLSE-05: 60 A continuous CLSE-10: 120 A continuous CLSE-20: 240 A continuous CLSE-40: 480 A continuous CLSE-60: 720 A continuous Be sure that the input voltage is of 480 V or less. INSTALLATION Current consumption: ≤90 mA Operating temperature: -10 to +55°C (14 to 131°F) Storage temperature: -10 to +55°C (14 to +131°F) Operating humidity: 10 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R10BS) Weight: 120 g (0.26 lb) except base PERFORMANCE Conversion accuracy: ±1 % except the sensor accuracy Conversion rate: 14 ms Data range CLSE-R5: Integer that engineering unit value (A) multiplied by 1000 CLSE-05, CLSE-10, CLSE-20: Integer that engineering unit value (A) multiplied by 100 CLSE-40, CLSE-60: Integer that engineering unit value (A) multiplied by 10 (Scaling of converted data is configurable with the configurator software) Temp. coefficient: ±0.03 %/°C (±0.02 %/°F) Response time: ≤ 2 sec. (0 – 90 %) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (input to Modbus to power input to FE1) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |