| Electronic Components Datasheet Search |
|
R3S-DC8S/Q Datasheet(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3S-DC8S/Q Datasheet(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 5 page ![]() MODEL: R3S-DC8 R3S-DC8 SPECIFICATIONS ES-8941 Rev.3 Page 1/5 https://www.m-system.co.jp/ Remote I/O R3 Series DISCRETE OUTPUT MODULE (Do 8 points (relay), tension clamp terminal block) 27.5 (1.08) 130 (5.12) mm (inch) 120 (4.72) MODEL: R3S–DC8[1][2] ORDERING INFORMATION • Code number: R3S-DC8[1][2] Specify a code from below for each of [1] and [2]. (e.g. R3S-DC8W/CE/Q) • Specify the specification for option code /Q (e.g. /C01) NO. OF CHANNELS 8: 8 [1] COMMUNICATION MODE S: Single W: Dual [2] OPTIONS (multiple selections) Standards & Approvals blank: Without CE /CE: CE marking Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R3-BSx) Output: Separable tension clamp terminal (applicable wire size: 0.2 to 1.5 mm2, stripped length 10 mm) Internal power: Via the Installation Base (model: R3-BSx) Isolation: Output 1 to output 2 to output 3 to output 4 to output 5 to output 6 to output 7 to output 8 to internal bus or internal power Output hold setting: Setting for communication error with side DIP SW RUN indicator: Bi-color (red/green) LED; Red when the bus A operates normally; Green when the bus B operates normally; Amber when both buses operate normally. ERR indicator: Green LED turns on in normal operating conditions. Output status indicator: 1 to 8: Red LED; turns on with the output ON. 9 to 16: Unused OUTPUT SPECIFICATIONS Output: Relay contact, 8 points Common: 1 point 1 common (8 terminals) Maximum load current: 2.0 A per point Relay driving power: 24 V DC ±10 %, ≥ 60 mA Maximum outputs applicable at once: No limit (at 24 V DC) Contact rating: 250 V AC @ 2 A (cos ø = 1) 30 V DC @ 2 A (resistive load) Maximum switching voltage: 250 V AC or 30 V DC Maximum switching power: 500 VA or 60 W Minimum load: 5 V DC @ 1 mA Mechanical life: 2 × 107 cycles (300 cycle/min.) When driving an inductive load, external protection is recommended. ON delay: ≤ 10 msec. OFF delay: ≤ 10 msec. INSTALLATION Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R3-BSx) Weight: 190 g (0.42 lb) |
Similar Part No. - R3S-DC8S/Q |
|
Similar Description - R3S-DC8S/Q |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |