| Electronic Components Datasheet Search |
|
ABC601 Datasheet(PDF) 2 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
ABC601 Datasheet(HTML) 2 Page - Bel Fuse Inc. |
|
2 / 11 page ![]() 2 ABC601 Series tech.support@psbel.com MODEL NUMBER PACKAGE & COOLING INPUT VOLTAGE RANGE [VAC] NOM. OUTPUT VOLTAGE [VDC] MAX. OUTPUT POWER [W] MAX. OUTPUT CURRENT [A] DIMENSIONS ABC601-1T24-S Enclosed Front Mounted Fan 85 - 305 24 600 25 107.0 x 206.0 x 41.0 mm 4.21 x 8.11 x 1.6 in ABC601-1T24 U-Chassis Convection / Forced Air 85 - 305 24 600 25 107.0 x 178.5 x 41.0 mm 4.21 x 7.03 x 1.61 in ABC601-1T28-S Enclosed Front Mounted Fan 85 - 305 28 600 21.4 107.0 x 206.0 x 41.0 mm 4.21 x 8.11 x 1.6 in ABC601-1T28 U-Chassis Convection / Forced Air 85 - 305 28 600 21.4 107.0 x 178.5 x 41.0 mm 4.21 x 7.03 x 1.61 in ABC601-1T36-S Enclosed Front Mounted Fan 85 - 305 36 600 16.7 107.0 x 206.0 x 41.0 mm 4.21 x 8.11 x 1.6 in ABC601-1T36 U-Chassis Convection / Forced Air 85 - 305 36 600 16.7 107.0 x 178.5 x 41.0 mm 4.21 x 7.03 x 1.61 in ABC601-1T48-S Enclosed Front Mounted Fan 85 - 305 48 600 12.5 107.0 x 206.0 x 41.0 mm 4.21 x 8.11 x 1.6 in ABC601-1T48 U-Chassis Convection / Forced Air 85 - 305 48 600 12.5 107.0 x 178.5 x 41.0 mm 4.21 x 7.03 x 1.61 in PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT AC Input Voltage PS starts and operates at 85 VAC at all load conditions 85 100-277 305 VRMS DC Input Voltage 170 - 300 VDC Input Frequency 440 Hz with reduced PFC and output power rating. Consult factory for details. 47 50/60 440 Hz Input Current RMS at 180 VAC, maximum load, 50 / 60 Hz RMS at 85 VAC, maximum load, 50 / 60 Hz - - 4.0 8.5 A Inrush Current Cold start, 25 °C ambient, full load 115 VAC 230 VAC - - - - 20 30 A Fusing High breaking, 10 A, 250 V on each AC lines. - - 10 A Efficiency 20% rated load 89 - - % At 115 VAC 50% rated load 93 - - 100% rated load 92 - - 20% rated load 90 - - At 230 / 277 VAC 50% rated load 94 - - 100% rated load 94 - - Input Power Consumption Power on, 115 VAC, no load Power on, 230 VAC, no load Stand by, 115, 230 VAC, no load - - - - - - 5 4 0.35 W Power Factor From 50 to 100% of rated load, 230, 115 VAC, 50 / 60 Hz input voltages. 0.90 - - - THDi From 50 to 100% rated load, 115, 230, 277 VAC 50 / 60 Hz. - - 20 % Harmonic Current Fluctuations and Flicker Complies with EN 61000-3-2 at 230 VAC, 50/60 Hz, Class A, D. Complies with EN 61000-3-2 Class C at 230 VAC, 50/60 Hz, >150 W load. Complies with EN 61000-3-3 at nominal voltages and full load. Earth Leakage Current Normal conditions 115 VRMS, 60 Hz 230 VRMS, 50 Hz 264 VRMS, 60 Hz (worst case) 277 VRMS, 60 Hz - - - - 130 240 - - - - 400 - µA Touch Leakage Current 264 VRMS, 60 Hz Normal Condition (NC) Single Fault Condition (SFC) - - - - 100 500 µA Patient Leakage Current 264 VRMS, 60 Hz Normal Condition (NC) Single Fault Condition (SFC) - - - - 100 500 µA |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |