4 / 20 page ![]() Setting the Output Voltage The MAX17410 has an internal digital-to-analog con- verter (DAC) that programs the output voltage. The out- put voltage can be digitally set from 0 to 1.5000V (Table 2) from the D0–D6 pins. There are two different ways of setting the output voltage: 1) Drive the external VID0–VID6 inputs (all SW1 posi- tions are off). The output voltage is set by driving VID0–VID6 with open-drain drivers (pullup resistors are included on the board) or 3V/5V CMOS output logic levels. 2) Switch SW1. When SW1 positions are off, the MAX17410’s D0–D6 inputs are at logic 1 (connect- ed to VDD). When SW1 positions are on, D0–D6 inputs are at logic 0 (connected to GND). The out- put voltage can be changed during operation by activating SW1 on and off. As shipped, the EV kit is configured with SW1 positions set for 0.9750V out- put (Table 2). Refer to the MAX17410 IC data sheet for more information. MAX17410 Evaluation Kit 4 _______________________________________________________________________________________ Table 1. MAX17410 Operating Mode Truth Table Functions INPUTS SHDN SW2 (1, 10) DPRSTP SW2 (5, 6) DPRSLPVR SW2 (2, 9) PSI SW2 (3, 8) PHASE OPERATION* OPERATING MODE GND X X X Disabled Low-Power Shutdown Mode. DL1 and DL2 are forced low and the controller is disabled. The supply current drops to 1µA (max). Rising X X X Multiphase Forced-PWM 1/8 RTIME Slew Rate Startup/Boot. When SHDN is pulled high, the MAX17410 begins the startup sequence. Once the REF is above 1.84V, the controller enables the PWM controller and ramps the output voltage up to the boot voltage. High X Low High Multiphase Forced-PWM Nominal RTIME Slew Rate Full Power. The no-load output voltage is determined by the selected VID DAC code (D0–D6, Table 2). High X Low Low 1-Phase Forced-PWM Nominal RTIME Slew Rate Intermediate Power. The no-load output voltage is determined by the selected VID DAC code (D0–D6, Table 2). When PSI is pulled low, the MAX17410 immediately disables phase 2. DH2 and DL2 are pulled low. High Low High X 1-Phase Pulse Skipping Nominal RTIME Slew Rate Deeper Sleep Mode. The no-load output voltage is determined by the selected VID DAC code (D0–D6, Table 2). When DPRSLPVR is pulled high, the MAX17410 immediately enters 1-phase pulse-skipping operation allowing automatic PWM/PFM switchover under light loads. The PWRGD and CLKEN upper thresholds are blanked. DH2 and DL2 are pulled low. High High High X 1-Phase Pulse Skipping 1/4 RTIME Slew Rate Deeper Sleep Slow Exit Mode. The no-load output voltage is determined by the selected VID DAC code (D0–D6, Table 2). When DPRSTP is pulled high while DPRSLPVR is already high, the MAX17410 remains in 1- phase pulse-skipping operation allowing automatic PWM/PFM switchover under light loads. The PWRGD and CLKEN upper thresholds are blanked. DH2 and DL2 are pulled low. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |