  TGL2210 Datasheet HTML 1Page - Qorvo, Inc TGL2210 Datasheet HTML 2Page - Qorvo, Inc TGL2210 Datasheet HTML 3Page - Qorvo, Inc TGL2210 Datasheet HTML 4Page - Qorvo, Inc TGL2210 Datasheet HTML 5Page - Qorvo, Inc TGL2210 Datasheet HTML 6Page - Qorvo, Inc TGL2210 Datasheet HTML 7Page - Qorvo, Inc TGL2210 Datasheet HTML 8Page - Qorvo, Inc TGL2210 Datasheet HTML 9Page - Qorvo, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 10 page
background image
TGL2210-SM
0.05 – 6.0 GHz 100 Watt VPIN Limiter
Data Sheet Rev. B, October 2, 2018 | Subject to change without notice
2 of 10
www.qorvo.com
®
Absolute Maximum Ratings
Parameter
Rating
Incident Power, Pulsed (PW = 10µs, DC
= 10%), 50
, 85 °C
110 W
Incident Power, CW, 50
, 25 °C
85 W
Incident Power, CW, 50
, 85 °C
70 W
Mounting Temperature
(30 s max)
260 °C
Storage Temperature
-55 to 150 °C
Exceeding any one or a combination of the Absolute Maximum Rating
conditions may cause permanent damage to the device. Extended
application of Absolute Maximum Rating conditions to the device may
reduce device reliability.
Electrical Specifications
Parameter
Conditions
Min
Typical
Max
Units
Operational Frequency Range
0.05
6.0
GHz
Insertion Loss, Un-Tuned
Freq = 3.5 GHz
0.6
0.85
dB
Insertion Loss, Tuned
Freq = 3.5 GHz (1)
0.4
dB
Input Return Loss, Un-Tuned
10
11
dB
Output Return Loss, Un-Tuned
 
10
11.5
dB
Flat Leakage Power
@ PIN > 30 dBm
< 17
dBm
Pulse Recovery Time
< 40
ns
Spike Leakage
< 0.5
dB
Insertion Loss Temperature Coefficient
0.001
dB/ °C
Notes:
Test conditions unless otherwise noted: Temp = +25 °C, 50 Ω system.
1.
Tuned EVB to improve 2-5 GHz
Thermal and Reliability Information
Parameter
Test Conditions
Value
Units
Incident Power
(168 hours RF Operational Life Test (1))
4.5 GHz, CW, 50
, 25 °C
31
W
4.5 GHz, Pulsed, PW=10 µs, DC=10%, 50
, 25 °C
100
W
Notes:
1.
Test was terminated at 168 hours. Insertion Loss remained
≤ 1 dB for device under test.
Recommended Operating Conditions
Parameter
Min
Typ
Max
Units
Operating Temperature Range
-40
+25
+85
°C
Passive
– No Bias
Electrical specifications are measured at specified test conditions.
Specifications are not guaranteed over all recommended operating
conditions.



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com