| Electronic Components Datasheet Search |
|
DA9318M Datasheet(PDF) 32 Page - Dialog Semiconductor |
|
|
|||||||||||||||||||||||||||||
DA9318M Datasheet(HTML) 32 Page - Dialog Semiconductor |
|
32 / 49 page ![]() DA9318L/M High-Efficiency, 10 A, High-Voltage Direct Charger Datasheet Revision 3.1 21-Apr-2021 CFR0011-120-00 32 of 49 © 2021 Dialog Semiconductor Bus clear, if the SDA is stuck, is achieved after receiving nine clock pulses. Operation in High-speed mode at 3.4 MHz requires a minimum interface supply voltage of 1.8 V and a mode change in order to enable spike suppression and slope control characteristics compatible to the I2C specification. The High-speed mode can be enabled on a transfer-by-transfer basis by sending the master code (0000 1XXX) at the beginning of the transfer. DA9318L/M does not make a use of clock stretching and delivers read data without additional delay up to 3.4 MHz. Alternatively the interface can be configured to use High-speed mode continuously via I2C_IF_HSM, so that the master code is not required at the beginning of every transfer. This reduces communication overhead on the bus, but limits the attachable bus slaves to compatible devices. 9.10.1 Details of the 2-Wire Protocol All data is transmitted across the 2-wire bus in 8-bit groups. To send a bit the SDA line is driven at the intended state while the SCL is low. Once the SDA has settled, the SCL line is brought high and then low. This pulse on SCL clocks the SDA bit into the receiver’s shift register. A two byte serial protocol is used containing one address byte and one data byte. Data and address transfer is transmitted MSB first for both read and write operations. All transmission begins with the START condition from the master during which the bus is in IDLE mode (the bus is free). It is initiated by a high-to-low transition on the SDA line, while the SCL is in the high state. A low-to-high transition on the SDA line, while the SCL is in the high state, indicates a STOP condition. Figure 15 illustrates the START and STOP conditions. START STOP SDA SCL Transaction Figure 15: START and STOP Condition Timing The 2-wire bus will be monitored by DA9318L/M for a valid slave address whenever the interface is enabled. It responds immediately when it receives its own slave address. This is acknowledged by pulling the SDA line low during the following clock cycle (white blocks marked with A in the following figures). The protocol for a register write from master to slave consists of a START condition, a slave address, a read/write-bit, 8-bit address, 8-bit data, and a STOP condition. DA9318L/M responds to all bytes with an A. Figure 16 illustrates a register write operation. SLAVEadr W REGadr A DATA A P S = START condition A = Acknowledge (low) P = STOP condition W = Write (low) Master to Slave Slave to Master 7-bits 1-bit 8-bits 8-bits A S Figure 16: Byte Write When the host reads data from a register it first has to write access DA9318L/M the target register address and then read access DA9318L/M with a Repeated START, or alternatively a second START, condition. After receiving the data, the host sends No Acknowledge and terminates the transmission with a STOP condition, see Figure 17. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |