| Electronic Components Datasheet Search |
|
LDW Datasheet(PDF) 8 Page - Shanghai Leiditech Electronic Technology Co., Ltd |
|
|
|||||||||||||||||||||||||||||
LDW Datasheet(HTML) 8 Page - Shanghai Leiditech Electronic Technology Co., Ltd |
|
8 / 9 page ![]() ■ Reliability 1-1.Mechanical Performance No Item Specification 1-1-1 Board Flex The forces applied on the right Refer to AEC-Q200-005 conditions must not damage Test device shall be soldered on the substrate the terminal electrode and the Substrate Dimension: 100x40x1.6mm ferrite Deflection: 2.0mm Keeping Time: 60sec 1-1-2 Resistance to Soldering Heat Appearance: No damage Refer to MIL-STD-202 Method 210 Inductance change shall be Pre-heating: 150℃, 1min within ±10%. Solder Composition: Sn/Ag3.0/Cu0.5(Pb-Free) Solder Temperature: 250±5℃ Immersion Time: 10±1sec 1-1-3 Solder ability The electrodes shall be at Refer to J-STD-002 least 95% covered with new Pre-heating: 150℃, 1min solder coating Solder Composition: Sn/Ag3.0/Cu0.5(Pb-Free) Solder Temperature: 245±5℃(Pb-Free) Immersion Time: 4±1sec 1-1-4 Terminal Strength Test Appearance: No damage Refer AEC-Q200-006 Soldered on PCB for testing as fig. Force : 1.8kg Keeping Time: 60 seconds. 1-1-5 Resistance to Solvent There must be no change in Refer to MIL-STD-202 Method 215 appearance or obliteration of Inductors must withstand 6 mimutes of alcohol or water. marking Sample Size : 15 pcs 1-1-6 Vibration Appearance: No damage Refer MIL-STD-202 Method 204 Inductance change shall be Vibration waveform: Sine waveform within ±10%. Vibration frequency: 10Hz~2000Hz Vibration acceleration: 5g Sweep rate: 0.764386otcave/minute Duration of test: 12 cycles each of 3 orientations, 20 minutes for each cycle Vibration axes: X, Y & Z 1-2.Environmental Performance No Item Specification 1-2-1 Temperature Cycle Appearance: No damage Refer to JESD Method JA-104 Inductance change shall be Total cycles: 1000 cycles within±30% Temperature Cycling Test Conditions : -40 to +125 ℃ -40 ℃ Soak Mode Condition : 30 minutes 125 ℃ Soak Mode Condition : 30 minutes Measured after exposure in the room condition for 24hrs 1-2-2 Biased Humidity Resistance Refer to MIL-STD-202 Method 103 Temperature: 85±2℃ Relative Humidity:85% / Time: 1000hrs Measured after exposure in the room condition for 24hrs 1-2-3 High Refer to MIL-STD-202 Method 108 Temperature Exposure Temperature: 125±3℃ / Relative Humidity: 0% (Storage) Applied Current: Rated Current /Time: 1000hrs Measured after exposure in the room condition for 24hrs 1-2-4 Operational Life Refer to MIL-STD-202 Method 108 Temperature: 85±3℃ Applied Current : Rated Current Time: 1000hrs Measured after exposure in the room condition for 24hrs Test Method Test Method LDW Series Rev : www.leiditech.com 01.06.2018 8/9 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |