Back Button LT3758 Datasheet HTML 14Page - Analog Devices LT3758 Datasheet HTML 15Page - Analog Devices LT3758 Datasheet HTML 16Page - Analog Devices LT3758 Datasheet HTML 17Page - Analog Devices LT3758 Datasheet HTML 18Page - Analog Devices LT3758 Datasheet HTML 19Page - Analog Devices LT3758 Datasheet HTML 20Page - Analog Devices LT3758 Datasheet HTML 21Page - Analog Devices LT3758 Datasheet HTML 22Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 48 page
background image
LTC7841
18
Rev. 0
For more information www.analog.com
OPERATION
The switching frequency of the LTC7841’s controllers can
be selected using the FREQ pin.
If the PLLIN/MODE pin is not being driven by an external
clock source, the FREQ pin can be tied to SGND, tied
to INTVCC, or programmed through an external resistor.
Tying FREQ to SGND selects 350kHz while tying FREQ
to INTVCC selects 535kHz. Placing a resistor between
FREQ and SGND allows the frequency to be programmed
between 50kHz and 900kHz, as shown in Figure 10.
A phase-locked loop (PLL) is available on the LTC7841
to synchronize the internal oscillator to an external clock
source that is connected to the PLLIN/MODE pin. The
LTC7841’s phase detector adjusts the voltage (through an
internal lowpass filter) of the VCO input to align the turn-
on of the first controller’s external bottom MOSFET to the
rising edge of the synchronizing signal. Thus, the turn-on
of the second controller’s external bottom MOSFET is 180
or 240 degrees out-of-phase to the rising edge of the
external clock source. When synchronized, the LTC7841
will operate in forced continuous mode of operation.
The VCO input voltage is prebiased to the operating fre-
quency set by the FREQ pin before the external clock is
applied. If prebiased near the external clock frequency,
the PLL loop only needs to make slight changes to the
VCO input in order to synchronize the rising edge of the
external clock’s to the rising edge of BG1. The ability to
prebias the loop filter allows the PLL to lock-in rapidly
without deviating far from the desired frequency.
The typical capture range of the LTC7841’s PLL is from
approximately 55kHz to 1MHz, and is guaranteed to lock
to an external clock source whose frequency is between
75kHz and 850kHz.
The typical input clock thresholds on the PLLIN/MODE
pin are 1.6V (rising) and 1.2V (falling). The recommended
maximum amplitude for low level and minimum ampli-
tude for high level of external clock are 0V and 2.5V,
respectively.
PolyPhase Applications (CLKOUT and PHASMD Pins)
The LTC7841 features two pins, CLKOUT and PHASMD,
that allow other controller ICs to be daisy-chained with
the LTC7841 in PolyPhase applications. The clock output
signal on the CLKOUT pin can be used to synchronize
additional power stages in a multiphase power supply
solution feeding a single, high current output or multiple
separate outputs. The PHASMD pin is used to adjust the
phase of the CLKOUT signal as well as the relative phases
between the two internal controllers, as summarized in
Table 2. The phases are calculated relative to the zero
degrees phase being defined as the rising edge of the bot-
tom gate driver output of controller 1 (BG1). Depending
on the phase selection, a PolyPhase application with mul-
tiple LTC7841s can be configured for 2-, 3-, 4- , 6- and
12-phase operation.
Table 2.
VPHASMD
CONTROLLER 2 PHASE (°)
CLKOUT PHASE (°)
GND
180
60
Floating
180
90
INTVCC
240
120
CLKOUT is disabled when the controller is in shutdown
or in sleep mode.
Operation When VIN > Regulated VOUT
When VIN rises above the regulated VOUT voltage, the
boost controller can behave differently depending on the
mode, inductor current and VIN voltage. In forced continu-
ous mode, the control loop works to keep the top MOSFET
on continuously once VIN rises above VOUT. The internal
charge pump delivers current to the boost capacitor to
maintain a sufficiently high TG voltage. The amount of cur-
rent the charge pump can deliver is characterized by two
curves in the Typical Performance Characteristics section.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com